Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Wind tunnel investigation on the two- and three-blade Savonius rotor with central shaft at different gap ratio
The Savonius rotor seems to be a promising wind turbine as it not only has the simplest and cheapest design but also is capable of yielding a higher annual energy output at low wind speed than the Darrieus rotor. Moreover, the Savonius rotor can also be used in ventilation systems, for local electricity production, as the start-up device for the Darrieus rotor, and small hydrokinetic turbines operating at low velocity. As a two-blade Savonius rotor suffers from negative average static torque coefficient (ACTS) at some azimuth angles and large-amplitude variation of ACTS, several studies have been conducted in recent years to improve ACTS. The three-blade rotor seems to be a potential candidate for ACTS improvement. However, less research has been done on three-blade rotors with a 180° arc and central shaft at different gap ratios (GRs) for different wind speeds. Therefore, the focus of the present work is to compare the two- and three-blade rotor in terms of ACTS and power coefficient (CP) through a wind tunnel experiment. Results show that the wind speed had a small effect on ACTS. However, negative azimuth angle range is narrowed and the negative azimuth angle range is moved upward as GR increased. Hence, the Savonius rotor with three blades could not only eliminate the negative range of ACTS but also smooth ACTS curves. In terms of the CP, the maximum power coefficient of the two-blade configuration was approximately 1.5 times that of the three-blade configuration. The 1/6 GR test data exhibited the attainment of super performance for all wind speed and blade number.
Wind tunnel investigation on the two- and three-blade Savonius rotor with central shaft at different gap ratio
The Savonius rotor seems to be a promising wind turbine as it not only has the simplest and cheapest design but also is capable of yielding a higher annual energy output at low wind speed than the Darrieus rotor. Moreover, the Savonius rotor can also be used in ventilation systems, for local electricity production, as the start-up device for the Darrieus rotor, and small hydrokinetic turbines operating at low velocity. As a two-blade Savonius rotor suffers from negative average static torque coefficient (ACTS) at some azimuth angles and large-amplitude variation of ACTS, several studies have been conducted in recent years to improve ACTS. The three-blade rotor seems to be a potential candidate for ACTS improvement. However, less research has been done on three-blade rotors with a 180° arc and central shaft at different gap ratios (GRs) for different wind speeds. Therefore, the focus of the present work is to compare the two- and three-blade rotor in terms of ACTS and power coefficient (CP) through a wind tunnel experiment. Results show that the wind speed had a small effect on ACTS. However, negative azimuth angle range is narrowed and the negative azimuth angle range is moved upward as GR increased. Hence, the Savonius rotor with three blades could not only eliminate the negative range of ACTS but also smooth ACTS curves. In terms of the CP, the maximum power coefficient of the two-blade configuration was approximately 1.5 times that of the three-blade configuration. The 1/6 GR test data exhibited the attainment of super performance for all wind speed and blade number.
Wind tunnel investigation on the two- and three-blade Savonius rotor with central shaft at different gap ratio
Chen, Liu (Autor:in) / Chen, Jian (Autor:in) / Xu, Hongtao (Autor:in) / Yang, Hongxing (Autor:in) / Ye, Changwen (Autor:in) / Liu, Di (Autor:in)
01.01.2016
15 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Wind tunnel tests on a savonius rotor
Elsevier | 1978
|BASE | 2020
|Harvesting wind energy for improving performance of Savonius rotor
Elsevier | 2015
|