Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental Evaluation of the Fire Performance of Simple Connections
This paper summarizes the results of experimental investigations on steel composite beams with simple connections at elevated temperatures. In the United States, three different types of simple connections are most commonly used in building construction with steel composite beams: (1) double-angle connections; (2) single-angle connections; and (3) shear-tab connections. A testing program was conducted to examine the structural behavior of all three of these connections at elevated temperatures. Each specimen consisted of a steel composite beam attached to a loading frame with simple connections. The specimens were subjected to controlled heating and cooling curves while the loading frames were fire protected and designed to remain in the elastic range. The shear-tab connections showed the largest connection rotation, but they fractured during the cooling phase of the tests. The prying of the angles in the double-angle and single-angle connection during the tests provided ductility to prevent fracture during the cooling phase of the experiments. The double-angle connections demonstrated the least connection rotation and excellent performance during the tests.
Experimental Evaluation of the Fire Performance of Simple Connections
This paper summarizes the results of experimental investigations on steel composite beams with simple connections at elevated temperatures. In the United States, three different types of simple connections are most commonly used in building construction with steel composite beams: (1) double-angle connections; (2) single-angle connections; and (3) shear-tab connections. A testing program was conducted to examine the structural behavior of all three of these connections at elevated temperatures. Each specimen consisted of a steel composite beam attached to a loading frame with simple connections. The specimens were subjected to controlled heating and cooling curves while the loading frames were fire protected and designed to remain in the elastic range. The shear-tab connections showed the largest connection rotation, but they fractured during the cooling phase of the tests. The prying of the angles in the double-angle and single-angle connection during the tests provided ductility to prevent fracture during the cooling phase of the experiments. The double-angle connections demonstrated the least connection rotation and excellent performance during the tests.
Experimental Evaluation of the Fire Performance of Simple Connections
Fischer, Erica C. (Autor:in) / Selden, Kristi L. (Autor:in) / Varma, Amit H. (Autor:in)
23.09.2016
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
The simple model for welded angle connections in fire
Online Contents | 2017
|The simple model for welded angle connections in fire
Springer Verlag | 2017
|The performance of frame connections in fire
British Library Conference Proceedings | 1999
|