Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Causes of and Responsibilities for an Excessive Amount of Leaking Cracks in a Massive Concrete Mat Foundation
Integral watertight concrete structures can be an effective and durable solution for underground facilities. The paper presents an evaluation of the major causes of and responsibilities for wide through cracks in a large mat foundation. A large number of leaking cracks with a width of up to 0.8 mm were observed in the mat foundation. Considering the importance of water leaking through the cracks in terms of the serviceability and durability of watertight concrete structures, emphasis is placed on the effect of early-age temperature rise in mat foundation. Mitigation strategies to prevent the formation and propagation of early-age through cracks are discussed. The concrete technology methods are aimed at reducing the concrete temperature by using low-heat generating concrete. In general, when assessing the risk of early-age cracking, drying and autogenous shrinkage may be ignored. The role of cement type, concrete cover and reinforcement to limit the width of cracks was analyzed.
Causes of and Responsibilities for an Excessive Amount of Leaking Cracks in a Massive Concrete Mat Foundation
Integral watertight concrete structures can be an effective and durable solution for underground facilities. The paper presents an evaluation of the major causes of and responsibilities for wide through cracks in a large mat foundation. A large number of leaking cracks with a width of up to 0.8 mm were observed in the mat foundation. Considering the importance of water leaking through the cracks in terms of the serviceability and durability of watertight concrete structures, emphasis is placed on the effect of early-age temperature rise in mat foundation. Mitigation strategies to prevent the formation and propagation of early-age through cracks are discussed. The concrete technology methods are aimed at reducing the concrete temperature by using low-heat generating concrete. In general, when assessing the risk of early-age cracking, drying and autogenous shrinkage may be ignored. The role of cement type, concrete cover and reinforcement to limit the width of cracks was analyzed.
Causes of and Responsibilities for an Excessive Amount of Leaking Cracks in a Massive Concrete Mat Foundation
Bilcik, Juraj (Autor:in) / Sonnenschein, Robert (Autor:in) / Holly, Ivan (Autor:in)
16.12.2017
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
British Library Online Contents | 2018
|Leaking of Concrete Roofs: Causes and Remedies
British Library Online Contents | 1996
|Unfavorable materials supply causes excessive amount of trucking
Engineering Index Backfile | 1931
Construction method for leaking stoppage of reinforced concrete cracks through electrolytic method
Europäisches Patentamt | 2024
|Foundation pit leaking stoppage construction method and leaking stoppage material
Europäisches Patentamt | 2021
|