Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms
Nail connections salvaged from the timber floor diaphragms of two old unreinforced masonry buildings were pseudostatically tested to determine their hysteretic behavior. The research objective was to establish expected load-slip characteristics of nail connections in historic timber diaphragms to facilitate improved seismic assessment accuracy. A summary of the testing procedure, test results, and performance characterization is presented. Nail connections constructed from Kauri (Agathis australis) timber and wire-drawn nails in the 1890s were found to have an average yield strength of 1.0 kN and an average maximum strength 1.4 kN. Nail connections constructed in 1914 from Rimu (Dacrydium cupressinum) timber and wire-drawn nails were found to have an average yield strength of 0.8 kN and an average maximum strength of 1.0 kN. Both connection types exhibited an average ultimate displacement capacity of approximately 11.4 mm.
Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms
Nail connections salvaged from the timber floor diaphragms of two old unreinforced masonry buildings were pseudostatically tested to determine their hysteretic behavior. The research objective was to establish expected load-slip characteristics of nail connections in historic timber diaphragms to facilitate improved seismic assessment accuracy. A summary of the testing procedure, test results, and performance characterization is presented. Nail connections constructed from Kauri (Agathis australis) timber and wire-drawn nails in the 1890s were found to have an average yield strength of 1.0 kN and an average maximum strength 1.4 kN. Nail connections constructed in 1914 from Rimu (Dacrydium cupressinum) timber and wire-drawn nails were found to have an average yield strength of 0.8 kN and an average maximum strength of 1.0 kN. Both connection types exhibited an average ultimate displacement capacity of approximately 11.4 mm.
Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms
Wilson, Aaron (Autor:in) / Quenneville, Pierre J. H. (Autor:in) / Moon, Franklin L. (Autor:in) / Ingham, Jason M. (Autor:in)
Journal of Materials in Civil Engineering ; 26 ; 202-205
01.02.2013
42014-01-01 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms
British Library Online Contents | 2014
|Lateral Performance of Nail Connections from Century-Old Timber Floor Diaphragms
Online Contents | 2014
|In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms
British Library Online Contents | 2010
|