Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Underground Outlet Works for Courtright and Wishon Dams
The diversion and outlet tunnel for Courtright Dam is in competent granite. It is unsupported and unlined. The outlet tower and trashrack are submerged. The outlet control is located in the tunnel at the axis of the dam and consists of: (1) a pipe embedded in a plug, (2) a butterfly valve in a dry chamber, (3) a cone-dispersion valve in a discharge chamber, and (4) an air-vent access shaft. Wishon Dam outlet works are similar.
Underground Outlet Works for Courtright and Wishon Dams
The diversion and outlet tunnel for Courtright Dam is in competent granite. It is unsupported and unlined. The outlet tower and trashrack are submerged. The outlet control is located in the tunnel at the axis of the dam and consists of: (1) a pipe embedded in a plug, (2) a butterfly valve in a dry chamber, (3) a cone-dispersion valve in a discharge chamber, and (4) an air-vent access shaft. Wishon Dam outlet works are similar.
Underground Outlet Works for Courtright and Wishon Dams
Cooke, J. B. (Autor:in) / Schumann, J. E. (Autor:in)
Journal of the Hydraulics Division ; 87 ; 27-40
01.01.2021
141961-01-01 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Filtrating Outlet Works for Rockfill Dams
Online Contents | 2018
|Filtrating Outlet Works for Rockfill Dams
Online Contents | 2018
|Filtrating Outlet Works for Rockfill Dams
Springer Verlag | 2018
|