Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Structural Review of Historic Perry Memorial Arch
Wiss, Janney, Elstner Associates (WJE) was engaged by the City of Bridgeport to perform a condition review of historic Perry Memorial Arch in preparation for a proposed restoration project. WJE performed an extensive field investigation to review the existing conditions at both the exterior and interior of the unreinforced masonry structure including a survey from an aerial lift and a small unmanned aerial system (sUAS/drone). Following the investigation of the structure, WJE used the findings to complete a structural analysis of the monument. The analysis included checks of overall stability when subjected to wind and seismic loading as well as shear and compression stress checks at the mortar joints of the masonry piers. WJE also utilized graphical methods to determine the stability of the unreinforced masonry arches. WJE’s analysis was simplified and conservative in nature with the goal of demonstrating to the client that the structure has adequate capacity to withstand the anticipated loads. Contrary to the findings of the previous engineer, WJE determined that the deterioration of the unreinforced masonry structure was caused by long-term water infiltration, saturated freeze-thaw cycling, and unaccommodated thermal movement of the masonry materials. WJE was engaged by the client to design repairs in accordance with the findings and recommendations of our analysis.
Structural Review of Historic Perry Memorial Arch
Wiss, Janney, Elstner Associates (WJE) was engaged by the City of Bridgeport to perform a condition review of historic Perry Memorial Arch in preparation for a proposed restoration project. WJE performed an extensive field investigation to review the existing conditions at both the exterior and interior of the unreinforced masonry structure including a survey from an aerial lift and a small unmanned aerial system (sUAS/drone). Following the investigation of the structure, WJE used the findings to complete a structural analysis of the monument. The analysis included checks of overall stability when subjected to wind and seismic loading as well as shear and compression stress checks at the mortar joints of the masonry piers. WJE also utilized graphical methods to determine the stability of the unreinforced masonry arches. WJE’s analysis was simplified and conservative in nature with the goal of demonstrating to the client that the structure has adequate capacity to withstand the anticipated loads. Contrary to the findings of the previous engineer, WJE determined that the deterioration of the unreinforced masonry structure was caused by long-term water infiltration, saturated freeze-thaw cycling, and unaccommodated thermal movement of the masonry materials. WJE was engaged by the client to design repairs in accordance with the findings and recommendations of our analysis.
Structural Review of Historic Perry Memorial Arch
Ariosto, Timothy (Autor:in) / Rakowski, Hannah (Autor:in)
Ninth Congress on Forensic Engineering ; 2022 ; Denver, Colorado
Forensic Engineering 2022 ; 294-301
02.11.2022
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Perry Bridge Network Arch—Elegance in Efficiency
Taylor & Francis Verlag | 2020
|Rebuilding a historic limestone arch
British Library Online Contents | 1999
Probabilistic-based structural assessment of a historic stone arch bridge
Taylor & Francis Verlag | 2021
|Hartford memorial bridge and arch
Engineering Index Backfile | 1898