Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Behavior of Postfabricated RC Beams under Monotonic Transverse Loading
Postfabricated beams, that is, newly constructed beams in an existing structural system, provide an effective remedial solution to the serviceability and strength problems in an existing floor system and the discontinuities and irregularities in the seismic-force-resisting system of a structure, mostly caused by design and construction errors or intended omissions of certain members. The purpose of this study is to develop new techniques for postfabrication of these beams and connecting the postfabricated beams to the existing columns and slab. In this respect, an experimental study was planned and a total of 16 half-scale specimens, including 3 monolithic (slab, columns, and beams cast monolithically) specimens and 13 specimens with postfabricated beams, were tested under monotonic vertical loads. The longitudinal reinforcement ratio of the postfabricated beam and the connection techniques of the postfabricated beam to the surrounding columns and slab constituted the test parameters. The tests indicated that the specimens with postfabricated beams were able to reach the strength and behavior of the monolithic specimens.
Behavior of Postfabricated RC Beams under Monotonic Transverse Loading
Postfabricated beams, that is, newly constructed beams in an existing structural system, provide an effective remedial solution to the serviceability and strength problems in an existing floor system and the discontinuities and irregularities in the seismic-force-resisting system of a structure, mostly caused by design and construction errors or intended omissions of certain members. The purpose of this study is to develop new techniques for postfabrication of these beams and connecting the postfabricated beams to the existing columns and slab. In this respect, an experimental study was planned and a total of 16 half-scale specimens, including 3 monolithic (slab, columns, and beams cast monolithically) specimens and 13 specimens with postfabricated beams, were tested under monotonic vertical loads. The longitudinal reinforcement ratio of the postfabricated beam and the connection techniques of the postfabricated beam to the surrounding columns and slab constituted the test parameters. The tests indicated that the specimens with postfabricated beams were able to reach the strength and behavior of the monolithic specimens.
Behavior of Postfabricated RC Beams under Monotonic Transverse Loading
Aykac, Sabahattin (Autor:in) / Jamal, Rohullah (Autor:in) / Ozbek, Eray (Autor:in) / Kalkan, Ilker (Autor:in) / Aykac, Bengi (Autor:in)
16.10.2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
BASE | 2020
|Behaviour Under Monotonic Loading
Springer Verlag | 2023
|Cold formed steel beams under monotonic and cyclic loading: Experimental investigation
Online Contents | 2009
|Performance of Laced Steel–Concrete Composite (LSCC) beams under monotonic loading
Online Contents | 2012
|Cold formed steel beams under monotonic and cyclic loading: Experimental investigation
Online Contents | 2009
|