Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Integrity of Bolted Angle Connections Subjected to Simulated Column Removal
Large-scale tests of steel gravity framing systems (SGFSs) have shown that the connections are critical to the system integrity when a column suffers damage that compromises its ability to carry gravity loads. When supporting columns were removed, the SGFSs redistributed gravity loads through the development of an alternate load path in a sustained tensile configuration resulting from large vertical deflections. The ability of the system to sustain such an alternate load path depends on the capacity of the gravity connections to remain intact after undergoing large rotation and axial extension demands for which they were not designed. This study experimentally evaluates the performance of steel bolted angle connections subjected to loading consistent with interior column removal. The characteristic connection behaviors are described and the performance of multiple connection configurations are compared in terms of their peak resistances and deformation capacities.
Integrity of Bolted Angle Connections Subjected to Simulated Column Removal
Large-scale tests of steel gravity framing systems (SGFSs) have shown that the connections are critical to the system integrity when a column suffers damage that compromises its ability to carry gravity loads. When supporting columns were removed, the SGFSs redistributed gravity loads through the development of an alternate load path in a sustained tensile configuration resulting from large vertical deflections. The ability of the system to sustain such an alternate load path depends on the capacity of the gravity connections to remain intact after undergoing large rotation and axial extension demands for which they were not designed. This study experimentally evaluates the performance of steel bolted angle connections subjected to loading consistent with interior column removal. The characteristic connection behaviors are described and the performance of multiple connection configurations are compared in terms of their peak resistances and deformation capacities.
Integrity of Bolted Angle Connections Subjected to Simulated Column Removal
Weigand, Jonathan M. (Autor:in) / Berman, Jeffrey W. (Autor:in)
08.12.2015
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Test, modeling and design of bolted-angle connections subjected to column removal
British Library Online Contents | 2017
|Test, modeling and design of bolted-angle connections subjected to column removal
British Library Online Contents | 2017
|Test, modeling and design of bolted-angle connections subjected to column removal
Online Contents | 2017
|Integrity of Steel Single Plate Shear Connections Subjected to Simulated Column Removal
British Library Online Contents | 2014
|