Lateral Strength Evaluation of Existing Oriented Strandboard Wall Sheathing
The lateral strength of thirty-six, 7/16 in thick oriented strandboard samples taken from two existing multi-story apartment buildings deemed to be in a state of substantial impairment in Western Washington state, USA were evaluated. These samples, although stained and partially deteriorated, met the minimum requirements for structural wood panels set forth by governmental and industry standards. A discussion of imminent collapse and substantial structural impairment and their relationships to the 1997 Uniform Code for Abatement of Dangerous buildings and the 2003 International Existing Building Code is presented as well as discussion on the economic burden created by the complete removal (stripping) of exterior wall claddings to replace oriented strandboard sheathing that still meets the minimum requirements for a structural wood panel.
Lateral Strength Evaluation of Existing Oriented Strandboard Wall Sheathing
The lateral strength of thirty-six, 7/16 in thick oriented strandboard samples taken from two existing multi-story apartment buildings deemed to be in a state of substantial impairment in Western Washington state, USA were evaluated. These samples, although stained and partially deteriorated, met the minimum requirements for structural wood panels set forth by governmental and industry standards. A discussion of imminent collapse and substantial structural impairment and their relationships to the 1997 Uniform Code for Abatement of Dangerous buildings and the 2003 International Existing Building Code is presented as well as discussion on the economic burden created by the complete removal (stripping) of exterior wall claddings to replace oriented strandboard sheathing that still meets the minimum requirements for a structural wood panel.
Lateral Strength Evaluation of Existing Oriented Strandboard Wall Sheathing
Simons, Kenneth B. (Autor:in)
Fourth Forensic Engineering Congress ; 2006 ; Cleveland, Ohio, United States
Forensic Engineering (2006) ; 467-475
03.10.2006
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Lateral Strength Evaluation of Existing Oriented Strandboard Wall Sheathing
British Library Conference Proceedings | 2007
|Fire Performance of Oriented Strandboard
British Library Conference Proceedings | 2006
|Stiffness and Strength Retention Properties of Structural Oriented Strandboard
British Library Conference Proceedings | 1998
|Nondestructive Evaluation of Biodegraded Oriented Strandboard: Laboratory Results
British Library Conference Proceedings | 2001
|