Nondestructive Bridge Deck Testing with Air-Coupled Impact-Echo and Infrared Thermography
Two different nondestructive test (NDT) methods, air-coupled impact-echo (IE) and infrared (IR) thermography are evaluated on a full-scale simulated reinforced concrete bridge deck containing simulated delamination and cracking defects. The IE data are presented as two-dimensional frequency maps and spectral B-scan lines. The IR data are presented as temperature maps on the concrete surface. The lateral boundaries of the detected delaminations are also indicated in the images. The results obtained from each of the individual NDT methods show reasonably good agreement with most of the actual defects. The advantages and limitations of each method to characterize defects are discussed. The consistency and sensitivity of each method are also investigated. Finally, a simple data fusion technique is proposed to improve effectiveness of the individual test data. The findings from this study demonstrate that the combination of air-coupled IE and IR thermography tests is a practical option for consistent and rapid in situ evaluation of reinforced concrete bridge decks.
Nondestructive Bridge Deck Testing with Air-Coupled Impact-Echo and Infrared Thermography
Two different nondestructive test (NDT) methods, air-coupled impact-echo (IE) and infrared (IR) thermography are evaluated on a full-scale simulated reinforced concrete bridge deck containing simulated delamination and cracking defects. The IE data are presented as two-dimensional frequency maps and spectral B-scan lines. The IR data are presented as temperature maps on the concrete surface. The lateral boundaries of the detected delaminations are also indicated in the images. The results obtained from each of the individual NDT methods show reasonably good agreement with most of the actual defects. The advantages and limitations of each method to characterize defects are discussed. The consistency and sensitivity of each method are also investigated. Finally, a simple data fusion technique is proposed to improve effectiveness of the individual test data. The findings from this study demonstrate that the combination of air-coupled IE and IR thermography tests is a practical option for consistent and rapid in situ evaluation of reinforced concrete bridge decks.
Nondestructive Bridge Deck Testing with Air-Coupled Impact-Echo and Infrared Thermography
Kee, Seong-Hoon (Autor:in) / Oh, Taekeun (Autor:in) / Popovics, John S. (Autor:in) / Arndt, Ralf W. (Autor:in) / Zhu, Jinying (Autor:in)
Journal of Bridge Engineering ; 17 ; 928-939
02.12.2011
122012-01-01 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Nondestructive Bridge Deck Testing with Air-Coupled Impact-Echo and Infrared Thermography
Online Contents | 2012
|Nondestructive Bridge Deck Testing with Air-Coupled Impact-Echo and Infrared Thermography
British Library Online Contents | 2012
|Active infrared thermography for bridge deck delamination detection
Tema Archiv | 2004
|Active Infrared Thermography for Bridge Deck Delamination Detection
British Library Conference Proceedings | 2004
|Active pulsed infrared thermography for concrete bridge deck inspection
Tema Archiv | 2001
|