Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Behavior of Pultruded Fiber-Reinforced Polymer Beams Subjected to Concentrated Loads in the Plane of the Web
Results of the behavior of pultruded fiber-reinforced polymer (FRP) I-shaped beams subjected to concentrated loads in the plane of the web are presented. Twenty beams with nominal depths from 152.4 to 304.8 mm were tested in three-point bending with a span-to-depth ratio of four. Load was applied to the top flange directly above the web—12 without bearing plates and 8 with bearing plates of varying width and thickness. All test specimens failed with a wedgelike shear failure at the upper web-flange junction. Finite-element results support experimental findings from strain gauge and digital image correlation data. Bearing plates increased beam capacity by 35&percent; or more as a function of bearing plate width and thickness. Bearing plates increased average shear stress in the web at failure from 17.4 to 27.2 MPa—below the accepted value of in-plane shear strength (69 MPa). A design equation is presented, and predicted capacities are compared with experimental results. The average value of experimental capacity to predicted capacity is 1.12 with a standard deviation of 0.11 and coefficient of variation (COV) of 0.10 for sections up to 304.8 mm deep.
Behavior of Pultruded Fiber-Reinforced Polymer Beams Subjected to Concentrated Loads in the Plane of the Web
Results of the behavior of pultruded fiber-reinforced polymer (FRP) I-shaped beams subjected to concentrated loads in the plane of the web are presented. Twenty beams with nominal depths from 152.4 to 304.8 mm were tested in three-point bending with a span-to-depth ratio of four. Load was applied to the top flange directly above the web—12 without bearing plates and 8 with bearing plates of varying width and thickness. All test specimens failed with a wedgelike shear failure at the upper web-flange junction. Finite-element results support experimental findings from strain gauge and digital image correlation data. Bearing plates increased beam capacity by 35&percent; or more as a function of bearing plate width and thickness. Bearing plates increased average shear stress in the web at failure from 17.4 to 27.2 MPa—below the accepted value of in-plane shear strength (69 MPa). A design equation is presented, and predicted capacities are compared with experimental results. The average value of experimental capacity to predicted capacity is 1.12 with a standard deviation of 0.11 and coefficient of variation (COV) of 0.10 for sections up to 304.8 mm deep.
Behavior of Pultruded Fiber-Reinforced Polymer Beams Subjected to Concentrated Loads in the Plane of the Web
Borowicz, David T. (Autor:in) / Bank, Lawrence C. (Autor:in)
Journal of Composites for Construction ; 15 ; 229-238
01.04.2011
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2011
|Web Buckling in Pultruded Fiber-Reinforced Polymer Deep Beams Subjected to Concentrated Loads
British Library Online Contents | 2014