Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Effect of Granular-Column Installation on Excess Pore Pressure Variation during Soil Liquefaction
During many earthquakes, soil liquefaction causes dramatic damage. The use of a granular column is a ground-improvement technique used to mitigate soil liquefaction. The present paper studies the performance of reinforcement with granular columns as a method for mitigation of potential risk of liquefaction during cyclic loading. The generation and dissipation of excess pore pressure are analyzed by considering the granular-column installation effect. This effect is described by a decrease in horizontal permeability within a disturbed zone around the column, which is described by constant, linear, and parabolic variations. The evolution of excess pore pressure is studied as a function of the disturbed zone in terms of reduced horizontal permeability. Obtained results show that a granular-column installation has a significant influence on the mitigation of liquefaction.
Effect of Granular-Column Installation on Excess Pore Pressure Variation during Soil Liquefaction
During many earthquakes, soil liquefaction causes dramatic damage. The use of a granular column is a ground-improvement technique used to mitigate soil liquefaction. The present paper studies the performance of reinforcement with granular columns as a method for mitigation of potential risk of liquefaction during cyclic loading. The generation and dissipation of excess pore pressure are analyzed by considering the granular-column installation effect. This effect is described by a decrease in horizontal permeability within a disturbed zone around the column, which is described by constant, linear, and parabolic variations. The evolution of excess pore pressure is studied as a function of the disturbed zone in terms of reduced horizontal permeability. Obtained results show that a granular-column installation has a significant influence on the mitigation of liquefaction.
Effect of Granular-Column Installation on Excess Pore Pressure Variation during Soil Liquefaction
Ben Salem, Z. (Autor:in) / Frikha, W. (Autor:in) / Bouassida, M. (Autor:in)
25.06.2015
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Effect of Granular-Column Installation on Excess Pore Pressure Variation during Soil Liquefaction
Online Contents | 2016
|Pore pressure during stone column installation
British Library Online Contents | 2012
|Observation of pore pressure and soil movements during lime column installation
British Library Conference Proceedings | 1999
|Understanding Excess Pore Water Dissipation in Soil Liquefaction Mitigation
British Library Conference Proceedings | 2022
|