Evaluating the Long-Term Durability of Externally Bonded FRP via Field Assessments
Fiber-reinforced polymer composites (FRP) are an attractive repair option for reinforced concrete structures, but whereas laboratory durability tests have indicated that FRP generally performs well in many environments, their long-term performance in field environments is not well understood. This case study describes an effort to collect in situ data about the FRP used to repair a concrete arch bridge 8 years after the FRP was originally placed. On-site assessment efforts included inspection for voids between the concrete and FRP using acoustic sounding and thermographic imaging and pull-off tests to check the bond strength. Large debonded regions of FRP were also cut from the structure and tested in tension in the laboratory. Results generally pointed to some level deterioration. Many new voids were found, existing voids had grown, pull-off testing showed weaker bond strengths, and the tensile strengths were quite low compared to design values. However, a lack of initial data make it difficult to distinguish between deterioration over time and the possibility of lower strengths because of field manufacture techniques.
Evaluating the Long-Term Durability of Externally Bonded FRP via Field Assessments
Fiber-reinforced polymer composites (FRP) are an attractive repair option for reinforced concrete structures, but whereas laboratory durability tests have indicated that FRP generally performs well in many environments, their long-term performance in field environments is not well understood. This case study describes an effort to collect in situ data about the FRP used to repair a concrete arch bridge 8 years after the FRP was originally placed. On-site assessment efforts included inspection for voids between the concrete and FRP using acoustic sounding and thermographic imaging and pull-off tests to check the bond strength. Large debonded regions of FRP were also cut from the structure and tested in tension in the laboratory. Results generally pointed to some level deterioration. Many new voids were found, existing voids had grown, pull-off testing showed weaker bond strengths, and the tensile strengths were quite low compared to design values. However, a lack of initial data make it difficult to distinguish between deterioration over time and the possibility of lower strengths because of field manufacture techniques.
Evaluating the Long-Term Durability of Externally Bonded FRP via Field Assessments
Allen, Douglas G. (Autor:in) / Atadero, Rebecca A. (Autor:in)
Journal of Composites for Construction ; 16 ; 737-746
30.04.2012
102012-01-01 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Evaluating the Long-Term Durability of Externally Bonded FRP via Field Assessments
British Library Online Contents | 2012
|Evaluating the Long-Term Durability of Externally Bonded FRP via Field Assessments
Online Contents | 2012
|Durability of reinforced concrete structures with externally bonded FRP sheets
British Library Conference Proceedings | 2004
|Long term durability of strengthened concrete with externally applied FRP composites
Tema Archiv | 2004
|