Postbuckling Shear Capacity of External Diaphragm Connections of CFST Structures
This paper presents experimental and analytical studies on the seismic behavior of beam-to-column connections with external diaphragms in the concrete-filled steel tubular (CFST) structures. Three cruciform joints between CFST column and H-shaped steel beam were tested subjected to a constant axial load on the column and a set of antisymmetrical cyclic loads at the beam’s tips to investigate the seismic behavior of the panel zone. A weak panel zone was specially considered in all three specimens to investigate the shear capacity of the panel zone. Key variables involved are the compressive strength of concrete and the axial load ratio. Three specimens all exhibited a shear failure in the panel zone due to local buckling. The strain distribution and load-displacement behaviors were discussed. In the analytical study, a computational model for the postbuckling shear capacity of panel zone was developed and checked for its applicability.
Postbuckling Shear Capacity of External Diaphragm Connections of CFST Structures
This paper presents experimental and analytical studies on the seismic behavior of beam-to-column connections with external diaphragms in the concrete-filled steel tubular (CFST) structures. Three cruciform joints between CFST column and H-shaped steel beam were tested subjected to a constant axial load on the column and a set of antisymmetrical cyclic loads at the beam’s tips to investigate the seismic behavior of the panel zone. A weak panel zone was specially considered in all three specimens to investigate the shear capacity of the panel zone. Key variables involved are the compressive strength of concrete and the axial load ratio. Three specimens all exhibited a shear failure in the panel zone due to local buckling. The strain distribution and load-displacement behaviors were discussed. In the analytical study, a computational model for the postbuckling shear capacity of panel zone was developed and checked for its applicability.
Postbuckling Shear Capacity of External Diaphragm Connections of CFST Structures
Rong, Bin (Autor:in) / Yang, Ziheng (Autor:in) / Zhang, Ruoyu (Autor:in) / Feng, Changxi (Autor:in) / Ma, Xu (Autor:in)
13.03.2019
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Experimental Study of the Shear Capacity of Steel Beam-to-L-CFST Column Connections
Springer Verlag | 2018
|Experimental Study of the Shear Capacity of Steel Beam-to-L-CFST Column Connections
Online Contents | 2018
|Experimental and Numerical Investigations of Bolted CFST Beams–CFST Columns Connections
Springer Verlag | 2018
|British Library Conference Proceedings | 2011
|Calculation method for the shear bearing capacity of diaphragm-through connections
Online Contents | 2016
|