Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Bearing Capacity Improvement Using Micropiles: A Case Study
Micropiles have been used effectively in many applications of ground improvement to increase the bearing capacity and reduce the settlements particularly in strengthening the existing foundations. Frictional resistance between the surface of the pile and soil and the associated group/network effects of micropiles are considered as the possible mechanism for improvement. This paper deals with a case study in which micropiles of 100 mm diameter and 4 m long have been used to improve the bearing capacity of foundation soil and in the rehabilitation of the total building foundation system. The micropiles were inserted around the individual footings at inclination of 70° with the horizontal. The actual design for retrofitting was based on the assumption that the vertical component of the frictional force between the soil and the micropile resists the additional load coming from the structure over and above the bearing capacity. The technique was successful and the structure did not show any signs of distress later. Detailed finite element analysis conducted validated the suggested treatment. The paper describes the case study, the method of treatment adopted in the field and the results of numerical analysis.
Bearing Capacity Improvement Using Micropiles: A Case Study
Micropiles have been used effectively in many applications of ground improvement to increase the bearing capacity and reduce the settlements particularly in strengthening the existing foundations. Frictional resistance between the surface of the pile and soil and the associated group/network effects of micropiles are considered as the possible mechanism for improvement. This paper deals with a case study in which micropiles of 100 mm diameter and 4 m long have been used to improve the bearing capacity of foundation soil and in the rehabilitation of the total building foundation system. The micropiles were inserted around the individual footings at inclination of 70° with the horizontal. The actual design for retrofitting was based on the assumption that the vertical component of the frictional force between the soil and the micropile resists the additional load coming from the structure over and above the bearing capacity. The technique was successful and the structure did not show any signs of distress later. Detailed finite element analysis conducted validated the suggested treatment. The paper describes the case study, the method of treatment adopted in the field and the results of numerical analysis.
Bearing Capacity Improvement Using Micropiles: A Case Study
Babu, G. L. Sivakumar (Autor:in) / Murthy, B. Srinivasa (Autor:in) / Murthy, D. S. N. (Autor:in) / Nataraj, M. S. (Autor:in)
GeoSupport Conference 2004 ; 2004 ; Orlando, Florida, United States
GeoSupport 2004 ; 692-699
23.01.2004
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Bearing Capacity Improvement Using Micropiles: A Case Study
British Library Conference Proceedings | 2003
|Analysis of bearing capacity improvement using micropiles
British Library Online Contents | 2002
|Computed and observed micropiles capacity (case studies)
British Library Conference Proceedings | 2002
|HIGH CAPACITY MICROPILES - BASIC PRINCIPLES AND CASE HISTORIES
British Library Conference Proceedings | 1999
|