Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Factors determining the quality of masonry – differentiation of resistance and reliability ; Czynniki determinujące jakość muru – różnicowanie wytrzymałości i niezawodności
A house or any other building without walls is truly hard to imagine. The first thing usually associated with walls is, of course, masonry. Today, masonry walls perform a load-bearing function in buildings up to four above-ground floors, in the higher parts of the buildings they perform a protective and stiffening function. However, there is awidespread opinion that the designer does not have to check the bearing capacity of masonry structures because masonry are were stand, are standing and will stand. Not everyone, however, currently works the wall as it should. The problem is that a lot of emphasis is now placed on reducing construction times. Therefore, there are a number of factors affecting the quality of the masonry structure, which overall reduce their safety. The article presents the influence of the quality of masonry on the differentiation of bearing capacity and reliability of an example masonry structure. The analyses included various values γm of the partial factor, recommended in the national annex PN-EN 1996-1, depending on the category of masonry units, class execution of works and type of mortar. In addition, a decrease in load capacity and reliability caused by the increase of the initial eccentric resulting from the inaccuracy of the masonry wall was examined. ; Ciężko wyobrazić sobie dom, budynek bez ścian. Jeżeli myślimy o ścianach, to pierwszym skojarzeniem są mury. Dziś mury pełnią funkcję nośną w budynkach do czterech kondygnacji nadziemnych, w wyższych partiach budynków pełnią funkcję osłonową i usztywniającą. Powszechnie panuje jednak jeszcze opinia, że konstruktor nie musi sprawdzać nośności konstrukcji murowych ponieważ mury stały, stoją i stać będą. Nie każdy jednak obecnie mur pracuje tak, jak powinien. Problem polega na tym, że obecnie duży nacisk kładzie się na skrócenie czasu wznoszenia budynków. W związku z tym pojawia się szereg czynników wpływających na jakość wykonania konstrukcji murowej, które sumarycznie wpływają na zmniejszenie ich bezpieczeństwa. W artykule przedstawiono wpływ jakości wykonania muru na różnicowanie nośności i niezawodności przykładowej konstrukcji murowej. W analizach uwzględniono różne wartości współczynnika bezpieczeństwa, rekomendowanego w załączniku krajowym PN-EN 1996-1 [1], uzależnione od kategorii elementów murowych, klasy robót murarskich oraz rodzaju zaprawy. Ponadto zbadano spadek nośności i niezawodności spowodowany zwiększeniem mimośrodu początkowego wynikającego z niedokładności wykonania ściany murowanej.
Factors determining the quality of masonry – differentiation of resistance and reliability ; Czynniki determinujące jakość muru – różnicowanie wytrzymałości i niezawodności
A house or any other building without walls is truly hard to imagine. The first thing usually associated with walls is, of course, masonry. Today, masonry walls perform a load-bearing function in buildings up to four above-ground floors, in the higher parts of the buildings they perform a protective and stiffening function. However, there is awidespread opinion that the designer does not have to check the bearing capacity of masonry structures because masonry are were stand, are standing and will stand. Not everyone, however, currently works the wall as it should. The problem is that a lot of emphasis is now placed on reducing construction times. Therefore, there are a number of factors affecting the quality of the masonry structure, which overall reduce their safety. The article presents the influence of the quality of masonry on the differentiation of bearing capacity and reliability of an example masonry structure. The analyses included various values γm of the partial factor, recommended in the national annex PN-EN 1996-1, depending on the category of masonry units, class execution of works and type of mortar. In addition, a decrease in load capacity and reliability caused by the increase of the initial eccentric resulting from the inaccuracy of the masonry wall was examined. ; Ciężko wyobrazić sobie dom, budynek bez ścian. Jeżeli myślimy o ścianach, to pierwszym skojarzeniem są mury. Dziś mury pełnią funkcję nośną w budynkach do czterech kondygnacji nadziemnych, w wyższych partiach budynków pełnią funkcję osłonową i usztywniającą. Powszechnie panuje jednak jeszcze opinia, że konstruktor nie musi sprawdzać nośności konstrukcji murowych ponieważ mury stały, stoją i stać będą. Nie każdy jednak obecnie mur pracuje tak, jak powinien. Problem polega na tym, że obecnie duży nacisk kładzie się na skrócenie czasu wznoszenia budynków. W związku z tym pojawia się szereg czynników wpływających na jakość wykonania konstrukcji murowej, które sumarycznie wpływają na zmniejszenie ich bezpieczeństwa. W artykule przedstawiono wpływ jakości wykonania muru na różnicowanie nośności i niezawodności przykładowej konstrukcji murowej. W analizach uwzględniono różne wartości współczynnika bezpieczeństwa, rekomendowanego w załączniku krajowym PN-EN 1996-1 [1], uzależnione od kategorii elementów murowych, klasy robót murarskich oraz rodzaju zaprawy. Ponadto zbadano spadek nośności i niezawodności spowodowany zwiększeniem mimośrodu początkowego wynikającego z niedokładności wykonania ściany murowanej.
Factors determining the quality of masonry – differentiation of resistance and reliability ; Czynniki determinujące jakość muru – różnicowanie wytrzymałości i niezawodności
Zięba , Joanna (Autor:in) / Buda-Ożóg, Lidia (Autor:in) / Skrzypczak, Izabela (Autor:in)
02.11.2020
doi:10.35784/bud-arch.2127
Budownictwo i Architektura; Vol 19 No 4 (2020); 127-138 ; Budownictwo i Architektura; Tom 19 Nr 4 (2020); 127-138 ; 2544-3275 ; 1899-0665
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Różnicowanie klas niezawodności konstrukcji z betonu
TIBKAT | 2003
|Czynniki obnizajace i podnoszace jakosc zycia w miastach
British Library Conference Proceedings | 1994
|Factors determining the quality of masonry – differentiation of resistance and reliability
DOAJ | 2020
|Kształtowanie struktury i wytrzymałości betonu
TIBKAT | 1993
|British Library Conference Proceedings | 2004
|