ANALISIS PENGGUNAAN DDC PADA SISTEM HVAC UNTUK MENINGKATKAN PENGHEMATAN KONSUMSI ENERGI DI HOTEL LANGHAM DISTRICT 8 SCBD JAKARTA
Heating System, Ventilanting and Air Conditioning (HVAC) or air conditioning systemsbecome one of the needs in high rise buildings in order to increase comfort in the room,differences in the level of comfort of each individual makes the HVAC system changes in loadpatterns that can result in wasteful use of electrical energy. This study aims to determine thesavings in the use of electrical energy with the use of DDC in the HVAC system at the Langhamhotel. DDC can regulate HVAC system supporting devices such as cooling towers, condenserwater pumps, chilled water pumps and chillers that aim to reduce the performance of the chillersso that energy savings are obtained. By using 2 work operation methods, the results of thecalculation of energy use obtained at the side of the chiller Langham hotel, with manualoperation without the use of DDC obtained a total consumption cost of IDR 3,409,290 andautomatic work operations using DDC obtained a total consumption cost of IDR 2,601,990 sothat it is obtained saving percentage of 24%.
ANALISIS PENGGUNAAN DDC PADA SISTEM HVAC UNTUK MENINGKATKAN PENGHEMATAN KONSUMSI ENERGI DI HOTEL LANGHAM DISTRICT 8 SCBD JAKARTA
Heating System, Ventilanting and Air Conditioning (HVAC) or air conditioning systemsbecome one of the needs in high rise buildings in order to increase comfort in the room,differences in the level of comfort of each individual makes the HVAC system changes in loadpatterns that can result in wasteful use of electrical energy. This study aims to determine thesavings in the use of electrical energy with the use of DDC in the HVAC system at the Langhamhotel. DDC can regulate HVAC system supporting devices such as cooling towers, condenserwater pumps, chilled water pumps and chillers that aim to reduce the performance of the chillersso that energy savings are obtained. By using 2 work operation methods, the results of thecalculation of energy use obtained at the side of the chiller Langham hotel, with manualoperation without the use of DDC obtained a total consumption cost of IDR 3,409,290 andautomatic work operations using DDC obtained a total consumption cost of IDR 2,601,990 sothat it is obtained saving percentage of 24%.
ANALISIS PENGGUNAAN DDC PADA SISTEM HVAC UNTUK MENINGKATKAN PENGHEMATAN KONSUMSI ENERGI DI HOTEL LANGHAM DISTRICT 8 SCBD JAKARTA
Hadi Chandra, Wibisana (Autor:in) / Swamardika, I.B Alit (Autor:in) / Maharta Pemayun, A.A Gede (Autor:in)
05.09.2020
doi:10.24843/SPEKTRUM.2020.v07.i03.p1
Jurnal SPEKTRUM; Vol 7 No 3 (2020): Jurnal SPEKTRUM; 1-7 ; 2684-9186 ; 2302-3163
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Studi konsumsi energi sebagai kajian awal untuk mengetahui & memonitor efisiensi penggunaan energi
BASE | 2012
|Pengaruh Penambahan Biopolimer Xanthan Gum untuk Mengurangi Konsumsi Energi pada Sistem Perpipaan
DOAJ | 2022
|DOAJ | 2023
|Analisis Peluang Penghematan Konsumsi Energi Pada Kantor Pertanahan Kota Kendari
BASE | 2019
|