Improved fire design model for walls and floors with I-joists
Wooden I-joists, being factory-made ultra-light and highly optimised products, are typically used as the load-bearing elements in timber frame assemblies (TFA), which consist of a combination of material layers – sheeting boards (claddings) and cavities which may be partially or completely filled with insulation. The materials used in conjunction with a timber member in a TFA affect the heating of the timber member. The joists consist of flanges (made of sawn wood, LVL or glulam) and a web (made of a wood - based board). Fire resistance of such wooden structural products is a complex matter. However, the current European design standard for timber structures in fire – Eurocode 5 Part 1-2 (2004) provides no guidance for I-joists. The fire resistance of wooden I-joists has been previously investigated by König (2006) and Schmid et al. (2011), who developed calculation models to analyse the load-bearing capacity of wooden I-joists exposed to fire for floors. There have been significant changes in the variety and types of materials used in conjunction with I-joists. Therefore, the application of these models is limited nowadays. Additionally, they focus on the reduced properties method. Only the effective cross-section method will be included in the revised Eurocode 5 Part 1-2. This report describes the unified model for wooden I-joists in both wall and floor assemblies which follows the philosophy of the effective cross-section method. Additionally, it should be used with all types of cavity insulation and fire protection systems. The unified I-joists model aims to be introduced to the new revised Eurocode 5 Part 1-2. Two phenomena have to be considered according to the ECSM: charring and mechanical resistance. It is assumed that the charring of wood is a material characteristic which is not dependent on the orientation of the structure (wall or floor). The charring of the flanges is primarily dependent on the cladding material and thickness. After the failure of the claddings, the charring is influenced by cavity ...
Improved fire design model for walls and floors with I-joists
Wooden I-joists, being factory-made ultra-light and highly optimised products, are typically used as the load-bearing elements in timber frame assemblies (TFA), which consist of a combination of material layers – sheeting boards (claddings) and cavities which may be partially or completely filled with insulation. The materials used in conjunction with a timber member in a TFA affect the heating of the timber member. The joists consist of flanges (made of sawn wood, LVL or glulam) and a web (made of a wood - based board). Fire resistance of such wooden structural products is a complex matter. However, the current European design standard for timber structures in fire – Eurocode 5 Part 1-2 (2004) provides no guidance for I-joists. The fire resistance of wooden I-joists has been previously investigated by König (2006) and Schmid et al. (2011), who developed calculation models to analyse the load-bearing capacity of wooden I-joists exposed to fire for floors. There have been significant changes in the variety and types of materials used in conjunction with I-joists. Therefore, the application of these models is limited nowadays. Additionally, they focus on the reduced properties method. Only the effective cross-section method will be included in the revised Eurocode 5 Part 1-2. This report describes the unified model for wooden I-joists in both wall and floor assemblies which follows the philosophy of the effective cross-section method. Additionally, it should be used with all types of cavity insulation and fire protection systems. The unified I-joists model aims to be introduced to the new revised Eurocode 5 Part 1-2. Two phenomena have to be considered according to the ECSM: charring and mechanical resistance. It is assumed that the charring of wood is a material characteristic which is not dependent on the orientation of the structure (wall or floor). The charring of the flanges is primarily dependent on the cladding material and thickness. After the failure of the claddings, the charring is influenced by cavity ...
Improved fire design model for walls and floors with I-joists
Mäger, Katrin Nele (Autor:in) / Just, Alar (Autor:in)
01.01.2022
FIRENWOOD D2.2
Paper
Elektronische Ressource
Englisch
Fire design of LSF floors using hollow flange channel joists
British Library Online Contents | 2016
|Fire design of LSF floors using hollow flange channel joists
British Library Online Contents | 2016
|British Library Online Contents | 1997
|Fire design of LSF floors using hollow flange channel joists
Online Contents | 2016
|Fire design of LSF floors using hollow flange channel joists
Elsevier | 2016
|