The Incidence of Sick Building Syndrome and Its Causes on Employees at the Governor’s Office of West Sulawesi Province
Introduction: Indoor air quality greatly affects human health because almost 90% of human life is indoors. Some symptoms that are often felt by employees in a building with Sick Building Syndrome (SBS) are fatigue; headaches; symptoms of eye, nose and throat irritation; skin irritation; dry cough, increased irritability and difficulty in concentration; nausea; drowsiness; and hypersensitivity to odor. This research aims to determine the relationship of air quality in space to the incidence of Sick Building Syndrome. Methods: This research was an analytic survey research with cross sectional approach. The samples in this study were employees who were in the Building D of the Provincial Governor's Office, West Sulawesi totalling 82 people. This research was carried out by measuring indoor air quality and giving questionnaires to find out the SBS events. Results: The results of room temperature measurements ranged from 26.14 - 41.46°C, humidity measurement was ≥ 60%, light intensity was ≤ 100 lux, the chemical quality of CO in the air was ≤ 29 mg/m3, CO2 levelin the air was ≤ 1000 ppm, and dust level was ≥ 0.15 mg/m3. Besides, there was a significant relationship between air temperature and dust levels on the incidence of Sick Building Syndrome (SBS), with p value of 0.006. Conclusion: It can be concluded that factors that influenced the occurrence of SBS were air temperature and dust concentration in the room.Keywords: indoor air quality, office, sick building syndrome
The Incidence of Sick Building Syndrome and Its Causes on Employees at the Governor’s Office of West Sulawesi Province
Introduction: Indoor air quality greatly affects human health because almost 90% of human life is indoors. Some symptoms that are often felt by employees in a building with Sick Building Syndrome (SBS) are fatigue; headaches; symptoms of eye, nose and throat irritation; skin irritation; dry cough, increased irritability and difficulty in concentration; nausea; drowsiness; and hypersensitivity to odor. This research aims to determine the relationship of air quality in space to the incidence of Sick Building Syndrome. Methods: This research was an analytic survey research with cross sectional approach. The samples in this study were employees who were in the Building D of the Provincial Governor's Office, West Sulawesi totalling 82 people. This research was carried out by measuring indoor air quality and giving questionnaires to find out the SBS events. Results: The results of room temperature measurements ranged from 26.14 - 41.46°C, humidity measurement was ≥ 60%, light intensity was ≤ 100 lux, the chemical quality of CO in the air was ≤ 29 mg/m3, CO2 levelin the air was ≤ 1000 ppm, and dust level was ≥ 0.15 mg/m3. Besides, there was a significant relationship between air temperature and dust levels on the incidence of Sick Building Syndrome (SBS), with p value of 0.006. Conclusion: It can be concluded that factors that influenced the occurrence of SBS were air temperature and dust concentration in the room.Keywords: indoor air quality, office, sick building syndrome
The Incidence of Sick Building Syndrome and Its Causes on Employees at the Governor’s Office of West Sulawesi Province
Adiningsih, Ridhayani (Autor:in) / Hairuddin, Miftah Chairani (Autor:in)
30.07.2021
doi:10.20473/ijosh.v10i2.2021.153-160
The Indonesian Journal Of Occupational Safety and Health; Vol 10, No 2 (2021): THE INDONESIAN JOURNAL OF OCCUPATIONAL SAFETY AND HEALTH; 153-160 ; 2540-7872 ; 2301-8046
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
DOAJ | 2023
|What causes sick building syndrome - sick workroom or sick dwelling?
British Library Conference Proceedings | 2000
|Sick building syndrome: causes and economic consequences
British Library Conference Proceedings | 1995
|Emerald Group Publishing | 1993
|Indoor environmental quality and Sick Building Syndrome in office buildings
DOAJ | 2018
|