Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparison of behaviour of laterally loaded round and squared timber bolted joints
In the current European standards for design of timber structures, the issue of timber-to-timber joint type is addressed only to squared timber, which makes the pinpointing of the round timber bolted joints load carrying capacity near-unfeasible due to the insufficient support in the current standards. There have been made series of tests of round timber joints in different inclinations of the loading force and also the reference tests of squared timber joints to compare the behaviour of this type of joints. Mechanical behaviour of the round and the squared timber bolted joints was tested in the laboratory of the Faculty of Civil Engineering in Ostrava. This paper presents results of static tests in tension at an angle of 0°, 90° and 60° to the grain of squared and round timber bolted joints. Load carrying capacity was determined according to the applicable standards and theories of fracture mechanics. The test results of laboratory tests were then compared with the results of theoretical calculations.
Comparison of behaviour of laterally loaded round and squared timber bolted joints
In the current European standards for design of timber structures, the issue of timber-to-timber joint type is addressed only to squared timber, which makes the pinpointing of the round timber bolted joints load carrying capacity near-unfeasible due to the insufficient support in the current standards. There have been made series of tests of round timber joints in different inclinations of the loading force and also the reference tests of squared timber joints to compare the behaviour of this type of joints. Mechanical behaviour of the round and the squared timber bolted joints was tested in the laboratory of the Faculty of Civil Engineering in Ostrava. This paper presents results of static tests in tension at an angle of 0°, 90° and 60° to the grain of squared and round timber bolted joints. Load carrying capacity was determined according to the applicable standards and theories of fracture mechanics. The test results of laboratory tests were then compared with the results of theoretical calculations.
Comparison of behaviour of laterally loaded round and squared timber bolted joints
Lokaj, Antonín (Autor:in) / Klajmonová, Kristýna (Autor:in)
15.12.2016
Frattura ed Integrità Strutturale; Vol. 11 No. 39 (2017): January 2017; Pages 56-61 ; Frattura ed Integrità Strutturale; V. 11 N. 39 (2017): January 2017; Pages 56-61 ; 1971-8993
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Round Timber Bolted Joints Reinforcement Methods
British Library Conference Proceedings | 2014
|Round Timber Bolted Joints Reinforcement Methods
Trans Tech Publications | 2014
|Round Timber Bolted Joints with Mechanical Reinforcement
Trans Tech Publications | 2013
|Reinforcement Possibilities of Round Timber Bolted Joints
Trans Tech Publications | 2014
|Round Timber Bolted Joints with Mechanical Reinforcement
British Library Conference Proceedings | 2014
|