Textile reinforced mortar versus reinforced FRP for confined concrete: Behaviour at elevated temperatures
Despite the clear advantages of confinement of concrete structural elements with fibre-reinforced polymers (FRPs) for strength and deformability enhancement, concerns as to their performance at elevated temperature, or in fire, remain. The results of a series of elevated temperature experiments on FRP and textile reinforced mortar (TRM) strengthening systems for confinement of circular concrete columns are presented. The behaviour and effectiveness of the respective confining systems is studied up to temperatures of 400°C. A total of 24 concrete cylinders were wrapped in the hoop direction with different amounts of FRP or TRM, heated to steady-state temperatures between 20 and 400°C, and loaded to failure in concentric axial compression under a steady-state thermal regime. The results indicate that the effectiveness of the FRP confining system bonded with epoxy decreased considerably, but did not vanish, with increasing temperatures, in particular within the region of the glass transition temperature of the epoxy resin/adhesive. Conversely, the TRM confining system, bonded with inorganic mortar rather than epoxy, demonstrated superior performance at 400°C as compared against tests performed at ambient temperature. Additional research is needed to better understand the reasons for this ; JRC.E.4-Safety and Security of Buildings
Textile reinforced mortar versus reinforced FRP for confined concrete: Behaviour at elevated temperatures
Despite the clear advantages of confinement of concrete structural elements with fibre-reinforced polymers (FRPs) for strength and deformability enhancement, concerns as to their performance at elevated temperature, or in fire, remain. The results of a series of elevated temperature experiments on FRP and textile reinforced mortar (TRM) strengthening systems for confinement of circular concrete columns are presented. The behaviour and effectiveness of the respective confining systems is studied up to temperatures of 400°C. A total of 24 concrete cylinders were wrapped in the hoop direction with different amounts of FRP or TRM, heated to steady-state temperatures between 20 and 400°C, and loaded to failure in concentric axial compression under a steady-state thermal regime. The results indicate that the effectiveness of the FRP confining system bonded with epoxy decreased considerably, but did not vanish, with increasing temperatures, in particular within the region of the glass transition temperature of the epoxy resin/adhesive. Conversely, the TRM confining system, bonded with inorganic mortar rather than epoxy, demonstrated superior performance at 400°C as compared against tests performed at ambient temperature. Additional research is needed to better understand the reasons for this ; JRC.E.4-Safety and Security of Buildings
Textile reinforced mortar versus reinforced FRP for confined concrete: Behaviour at elevated temperatures
CERNIAUSKAS Gabrielis (Autor:in) / TETTA Zoi (Autor:in) / BOURNAS DIONYSIOS (Autor:in) / BISBY Luke (Autor:in)
28.06.2016
Sonstige
Elektronische Ressource
Englisch
DDC:
690
Textile-Reinforced Mortar versus Fiber-Reinforced Polymer Confinement in Reinforced Concrete Columns
Online Contents | 2007
|Textile-reinforced mortar (TRM) versus FRP jacketing for reinforced concrete columns
British Library Conference Proceedings | 2007
|Textile Reinforced Mortar at High Temperatures
Tema Archiv | 2011
|Behaviour of Textile-Reinforced Concrete Beams versus Steel-Reinforced Concrete Beams
DOAJ | 2021
|Concrete Confinement with Textile-Reinforced Mortar Jackets
Online Contents | 2006
|