Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Shaking table tests of a two-storey log house
This paper presents the findings of an experimental campaign that was conducted to investigate the seismic behaviour of log houses. A two-storey log house designed by the Portuguese company Rusticasa® was subjected to a series of shaking table tests at LNEC, Lisbon, Portugal. The paper contains the description of the geometry and construction of the house and all the aspects related to the testing procedure, namely the pre-design, the setup, instrumentation and the testing process itself. The shaking table tests were carried out with a scaled spectrum of the Montenegro (1979) earthquake, at increasing levels of PGA, starting from 0.07g, moving on to 0.28g and finally 0.5g. The log house did not suffer any major damage and remained in working condition throughout the entire process. The preliminary analysis of the overall behaviour of the log house is also discussed. ; Acknowledgement to 'Series': the research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 227887 (Series).
Shaking table tests of a two-storey log house
This paper presents the findings of an experimental campaign that was conducted to investigate the seismic behaviour of log houses. A two-storey log house designed by the Portuguese company Rusticasa® was subjected to a series of shaking table tests at LNEC, Lisbon, Portugal. The paper contains the description of the geometry and construction of the house and all the aspects related to the testing procedure, namely the pre-design, the setup, instrumentation and the testing process itself. The shaking table tests were carried out with a scaled spectrum of the Montenegro (1979) earthquake, at increasing levels of PGA, starting from 0.07g, moving on to 0.28g and finally 0.5g. The log house did not suffer any major damage and remained in working condition throughout the entire process. The preliminary analysis of the overall behaviour of the log house is also discussed. ; Acknowledgement to 'Series': the research leading to these results has received funding from the European Union's Seventh Framework Programme (FP7/2007-2013) under grant agreement no. 227887 (Series).
Shaking table tests of a two-storey log house
Branco, Jorge M. (Autor:in) / Lourenço, Paulo B. (Autor:in) / Aranha, Chrysl Assumpta (Autor:in)
01.09.2015
doi:10.1680/stbu.14.00017
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Shaking Table Tests on Damage Detection of Multi-Storey Buildings
British Library Conference Proceedings | 1994
|Shaking table tests on 3-storey wood-concrete hybrid structure
British Library Online Contents | 2008
|Shaking table tests of a 3-storey self-centring steel MRF: preliminary analysis and design
BASE | 2024
|