Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparative Study of the Static and Dynamic Analysis of Multi-Storey Irregular Building
As the world move to the accomplishment of Performance Based Engineering philosophies in seismic design of Civil Engineering structures, new seismic design provisions require Structural Engineers to perform both static and dynamic analysis for the design of structures. While Linear Equivalent Static Analysis is performed for regular buildings up to 90m height in zone I and II, Dynamic Analysis should be performed for regular and irregular buildings in zone IV and V. Dynamic Analysis can take the form of a dynamic Time History Analysis or a linear Response Spectrum Analysis. In present study, Multi-storey irregular buildings with 20 stories have been modeled using software packages ETABS and SAP 2000 v.15 for seismic zone V in India. This paper also deals with the effect of the variation of the building height on the structural response of the shear wall building. Dynamic responses of building under actual earthquakes, EL-CENTRO 1949 and CHI-CHI Taiwan 1999 have been investigated. This paper highlights the accuracy and exactness of Time History analysis in comparison with the most commonly adopted Response Spectrum Analysis and Equivalent Static Analysis.
Comparative Study of the Static and Dynamic Analysis of Multi-Storey Irregular Building
As the world move to the accomplishment of Performance Based Engineering philosophies in seismic design of Civil Engineering structures, new seismic design provisions require Structural Engineers to perform both static and dynamic analysis for the design of structures. While Linear Equivalent Static Analysis is performed for regular buildings up to 90m height in zone I and II, Dynamic Analysis should be performed for regular and irregular buildings in zone IV and V. Dynamic Analysis can take the form of a dynamic Time History Analysis or a linear Response Spectrum Analysis. In present study, Multi-storey irregular buildings with 20 stories have been modeled using software packages ETABS and SAP 2000 v.15 for seismic zone V in India. This paper also deals with the effect of the variation of the building height on the structural response of the shear wall building. Dynamic responses of building under actual earthquakes, EL-CENTRO 1949 and CHI-CHI Taiwan 1999 have been investigated. This paper highlights the accuracy and exactness of Time History analysis in comparison with the most commonly adopted Response Spectrum Analysis and Equivalent Static Analysis.
Comparative Study of the Static and Dynamic Analysis of Multi-Storey Irregular Building
Bahador Bagheri (Autor:in) / Ehsan Salimi Firoozabad (Autor:in) / Mohammadreza Yahyaei (Autor:in)
27.11.2012
oai:zenodo.org:1057737
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Comfort level identification for irregular multi-storey building
British Library Online Contents | 2015
|Comfort level identification for irregular multi-storey building
Online Contents | 2015
|A performance based seismic analysis of irregular multi-storey building with soft-storey: A review
American Institute of Physics | 2019
|Comfort Level Identification for Irregular Multi-storey Building Subjected to Vibrations
Online Contents | 2015
|