Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Shaking table tests validating two strengthening interventions on masonry buildings
Masonry buildings constitute quite often a precious cultural heritage for our cities. In order to future generations can enjoy this heritage, thence, effective projects of protection should be developed against all the anthropical and natural actions which may irreparably damage old masonry buildings. However, the strengthening interventions on these constructions have to respect their authenticity, without altering the original conception, not only functionally and aesthetically of course, but also statically. These issues are of central interests in the Messina area, where the seismic protection of new and existing constructions is a primary demand. It is well known, in fact, that the city of Messina lies in a highly seismic zone, and has been subjected to two destructive earthquakes in slightly more than one century, the 1783 Calabria earthquake and the more famous 1908 Messina-Reggio Calabria earthquake. It follows that the retrofitting projects on buildings which survived these two events should be designed with the aim to save the life of occupants operating with light techniques, i.e. respecting the original structural scheme. On the other hand, recent earthquakes, and in particular the 1997 Umbria-Marche sequence, unequivocally demonstrated that some of the most popular retrofitting interventions adopted in the second half the last century are absolutely ineffective, or even unsafe. Over these years, in fact, a number of heavy techniques proliferated, and therefore old masonry buildings suffered, among others, the substitution of existing timber slabs with more ponderous concrete slabs and/or the insertion of RC and steel members coupled with the original masonry elements (walls, arches, vaults). As a result, these buildings have been transformed by unwise engineers into hybrid structures, having a mixed behaviour (which frequently proved to be also unpredictable) between those of historic masonry and new members. Starting from these considerations, a numerical and experimental research has been carried ...
Shaking table tests validating two strengthening interventions on masonry buildings
Masonry buildings constitute quite often a precious cultural heritage for our cities. In order to future generations can enjoy this heritage, thence, effective projects of protection should be developed against all the anthropical and natural actions which may irreparably damage old masonry buildings. However, the strengthening interventions on these constructions have to respect their authenticity, without altering the original conception, not only functionally and aesthetically of course, but also statically. These issues are of central interests in the Messina area, where the seismic protection of new and existing constructions is a primary demand. It is well known, in fact, that the city of Messina lies in a highly seismic zone, and has been subjected to two destructive earthquakes in slightly more than one century, the 1783 Calabria earthquake and the more famous 1908 Messina-Reggio Calabria earthquake. It follows that the retrofitting projects on buildings which survived these two events should be designed with the aim to save the life of occupants operating with light techniques, i.e. respecting the original structural scheme. On the other hand, recent earthquakes, and in particular the 1997 Umbria-Marche sequence, unequivocally demonstrated that some of the most popular retrofitting interventions adopted in the second half the last century are absolutely ineffective, or even unsafe. Over these years, in fact, a number of heavy techniques proliferated, and therefore old masonry buildings suffered, among others, the substitution of existing timber slabs with more ponderous concrete slabs and/or the insertion of RC and steel members coupled with the original masonry elements (walls, arches, vaults). As a result, these buildings have been transformed by unwise engineers into hybrid structures, having a mixed behaviour (which frequently proved to be also unpredictable) between those of historic masonry and new members. Starting from these considerations, a numerical and experimental research has been carried ...
Shaking table tests validating two strengthening interventions on masonry buildings
De Canio G. (Autor:in) / Muscolino G. (Autor:in) / Palmeri A. (Autor:in) / Poggi M. (Autor:in) / Clemente P. (Autor:in) / De Canio, G. / Muscolino, G. / Palmeri, A. / Poggi, M. / Clemente, P.
01.01.2008
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
DDC:
690
Shaking Table Tests Validating Two Strengthening Interventions on Masonry Buildings
British Library Conference Proceedings | 2008
|SHAKING TABLE TESTS OF STONE MASONRY BUILDINGS
British Library Conference Proceedings | 2010
|Shaking Table Tests on 24 Simple Masonry Buildings
Online Contents | 1998
|Shaking table tests on strengthening of masonry structures against earthquake hazard
BASE | 2010
|