Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Comparison of Hexagrid and Diagrid Structural System in Tall Buildings
The taller and higher structures results in the effects of lateral loading, lateral loads dominates when the height of building increases, lateral loads such as earthquake, wind causes the building larger displacement, to avoid larger displacement in high rise buildings lateral load resisting systems are deployed. Apart from other structural system, the diagrid and hexagrid system are adopted to improve structural performance of tall buildings. The various types of structural system in tall buildings have become obsolete and the new structural skeletons such as hexagrid and diagrid are being used. The present research shows analysis of 40 storey steel structure with composite columns with diagrid and hexagrid structural system along the periphery has been modelled in ETABS v.16 software. The structure is situated in zone II, both the model diagrid as well as hexagrid has been analysed for same gravity loading. The parameters such as displacement, base shear, storey drift, displacement due to wind. Equivalent static method is use
Comparison of Hexagrid and Diagrid Structural System in Tall Buildings
The taller and higher structures results in the effects of lateral loading, lateral loads dominates when the height of building increases, lateral loads such as earthquake, wind causes the building larger displacement, to avoid larger displacement in high rise buildings lateral load resisting systems are deployed. Apart from other structural system, the diagrid and hexagrid system are adopted to improve structural performance of tall buildings. The various types of structural system in tall buildings have become obsolete and the new structural skeletons such as hexagrid and diagrid are being used. The present research shows analysis of 40 storey steel structure with composite columns with diagrid and hexagrid structural system along the periphery has been modelled in ETABS v.16 software. The structure is situated in zone II, both the model diagrid as well as hexagrid has been analysed for same gravity loading. The parameters such as displacement, base shear, storey drift, displacement due to wind. Equivalent static method is use
Comparison of Hexagrid and Diagrid Structural System in Tall Buildings
Farhan Danish (Autor:in) / D. H. Tupe (Autor:in) / G. R. Gandhe (Autor:in)
15.12.2018
oai:zenodo.org:2292662
Journal of Structural Technology 3(3) 55-61
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Diagrid Structures for Complex-Shaped Tall Buildings
Tema Archiv | 2012
|A review of the diagrid structural system for tall buildings
Wiley | 2018
|Diagrid Structures for Complex-Shaped Tall Buildings
British Library Conference Proceedings | 2012
|Parametric design of diagrid tall buildings regarding structural efficiency
Taylor & Francis Verlag | 2020
|Diagrid Structures for Complex-Shaped Tall Buildings
Trans Tech Publications | 2012
|