PARAMETRIC STUDY OF BASE ISOLATION SYSTEM FOR ELEVATED WATER TANK
Forimprovement of seismic performance of the structures base isolation technique is generally used, inwhich base isolators are placed between foundation and the base soil. In this paper comparative study of three types of base isolations viz. elastomeric bearing, laminated rubber bearing and friction pendulum system for elevated water tank is carried out to study impact of various base isolators on seismicbehavior of elevated water tank. Elevated water tanks of three different capacities with tank full,tank partially full and tank emptycoditionsare considered. The dynamic characteristics of the base-isolated elevated water tanks are obtained for parametric study. It is found that the partially full condition is critical, due to sloshing effect. Moreover it is worthy to note that for the maximum period of time the tank is in partially full condition. The seismic performance of elevated water tank without base isolation and with base isolation systems are evaluated and compared. The effectiveness of isolation system on different capacities of the water tanks is presented. From the present study it is concluded that the laminated rubber bearing base isolator gives better performance for the elevated water tank.
PARAMETRIC STUDY OF BASE ISOLATION SYSTEM FOR ELEVATED WATER TANK
Forimprovement of seismic performance of the structures base isolation technique is generally used, inwhich base isolators are placed between foundation and the base soil. In this paper comparative study of three types of base isolations viz. elastomeric bearing, laminated rubber bearing and friction pendulum system for elevated water tank is carried out to study impact of various base isolators on seismicbehavior of elevated water tank. Elevated water tanks of three different capacities with tank full,tank partially full and tank emptycoditionsare considered. The dynamic characteristics of the base-isolated elevated water tanks are obtained for parametric study. It is found that the partially full condition is critical, due to sloshing effect. Moreover it is worthy to note that for the maximum period of time the tank is in partially full condition. The seismic performance of elevated water tank without base isolation and with base isolation systems are evaluated and compared. The effectiveness of isolation system on different capacities of the water tanks is presented. From the present study it is concluded that the laminated rubber bearing base isolator gives better performance for the elevated water tank.
PARAMETRIC STUDY OF BASE ISOLATION SYSTEM FOR ELEVATED WATER TANK
DR.HALKUDE S.A (Autor:in) / DR. PATIL S.S (Autor:in) / MR. KONAPURE C.G (Autor:in)
27.03.2021
International Journal of Innovations in Engineering Research and Technology; Vol. 5 No. 4 (2018): IJIERT; 1-11 ; 2394-3696
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Seismic Response Mitigation of Elevated Water Storage Tank Using Base Isolation System
Springer Verlag | 2022
|Seismic Response of Elevated Cylindrical Water Tank with Lead Rubber Bearing Isolation System
Springer Verlag | 2024
|