Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
The Effectiveness Investigation of Evaporative Cooling Using Radiator for Pre-Cooling System
Due to the mechanical vapor compression systems are have a high energy consumption for air-conditioned space. And the evaporative cooling system are more interested to use as alternative system for air-conditioning system. Moreover, the pre-cooling system are normally use to reduce intake ambient air temperature before air-conditioning system.From above mentioned, this research propose to investigate the effectiveness of evaporative cooling system by using car radiator for air pre-cooling. The commercial car radiator was used for cooling inlet ambient air by cooling water. The evaporative cooling system consists of evaporative cooling panel which water maximum rate 40 lite/minute and air maximum rate 5,100 m3/hr.The result show that the most suitable water flow rate of radiator is 10 lite/minute that radiator can make temperature different of air about 8.9 °C, the effectiveness is about 73.31 % which maximum sensible heat of 8.43 kW.
The Effectiveness Investigation of Evaporative Cooling Using Radiator for Pre-Cooling System
Due to the mechanical vapor compression systems are have a high energy consumption for air-conditioned space. And the evaporative cooling system are more interested to use as alternative system for air-conditioning system. Moreover, the pre-cooling system are normally use to reduce intake ambient air temperature before air-conditioning system.From above mentioned, this research propose to investigate the effectiveness of evaporative cooling system by using car radiator for air pre-cooling. The commercial car radiator was used for cooling inlet ambient air by cooling water. The evaporative cooling system consists of evaporative cooling panel which water maximum rate 40 lite/minute and air maximum rate 5,100 m3/hr.The result show that the most suitable water flow rate of radiator is 10 lite/minute that radiator can make temperature different of air about 8.9 °C, the effectiveness is about 73.31 % which maximum sensible heat of 8.43 kW.
The Effectiveness Investigation of Evaporative Cooling Using Radiator for Pre-Cooling System
aupakham, srithorn (Autor:in) / thiangchanta, surasit (Autor:in)
14.12.2018
วารสารวิชาการและวิจัย มทร.พระนคร; Vol 12 No 2 (2018): July - December 2018; 1-9 ; RMUTP Research Journal; Vol 12 No 2 (2018): July - December 2018; 1-9 ; 2651-1096 ; 1906-0432
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Taylor & Francis Verlag | 1964
|Experimental investigation of air conditioning system using evaporative cooling condenser
Online Contents | 2014
|