Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Efficient Operation of Lithium-Ion Batteries Based on GPV-Forecasted PV Output
Load forecasting is essential in order to fulfil a demand of the consumer. Nevertheless, for a small-scale Battery Energy Storage System (BESS) based on sole photovoltaic (PV), it needs a very strong effort to always meet a consumer's demand due to unstable meteorological conditions. An ideal PV system requires a constructive control strategy in order to alleviate its fluctuating output. In this study, an energy control scheme that executes next-day forecast of generation for the purpose of fully utilizing the stored energy in the batteries has been proposed. Experimental equipment was structured and the operation was completely administered by RX621 microcontroller. The implemented system worked very well without any distractions and it succeeded in controlling and preventing the batteries from being over-charged or overdischarged. Impressively, average consumption for September 2015 is considerably high, which suggests that the proposed control succeeded in utilizing energy corresponded to 98.6 % of the monthly-average generation.
Efficient Operation of Lithium-Ion Batteries Based on GPV-Forecasted PV Output
Load forecasting is essential in order to fulfil a demand of the consumer. Nevertheless, for a small-scale Battery Energy Storage System (BESS) based on sole photovoltaic (PV), it needs a very strong effort to always meet a consumer's demand due to unstable meteorological conditions. An ideal PV system requires a constructive control strategy in order to alleviate its fluctuating output. In this study, an energy control scheme that executes next-day forecast of generation for the purpose of fully utilizing the stored energy in the batteries has been proposed. Experimental equipment was structured and the operation was completely administered by RX621 microcontroller. The implemented system worked very well without any distractions and it succeeded in controlling and preventing the batteries from being over-charged or overdischarged. Impressively, average consumption for September 2015 is considerably high, which suggests that the proposed control succeeded in utilizing energy corresponded to 98.6 % of the monthly-average generation.
Efficient Operation of Lithium-Ion Batteries Based on GPV-Forecasted PV Output
Mohd Shah, Ahmad Syahiman (Autor:in) / Abdul Karim, Mohamad Shaiful (Autor:in) / Jadin, Mohd Shawal (Autor:in) / Abdullah, Airul Sharizli (Autor:in) / Ishak, Ruhaizad (Autor:in) / Ishikawa, Yuki (Autor:in) / Takahashi, Hiroki (Autor:in) / Odakura, Suguru (Autor:in) / Kakimoto, Naoto (Autor:in) / Japan Meteorology Agency
18.01.2018
Journal of Telecommunication, Electronic and Computer Engineering (JTEC); Vol 10, No 1-2: Moving Towards Industry 4.0 I; 161-167 ; 2289-8131 ; 2180-1843
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
A Retrospective Comparison of Model-Based Forecasted PM2.5 Concentrations with Measurements
Taylor & Francis Verlag | 2010
|Forecasted Scenarios of Regional Wind Farms Based on Regular Vine Copulas
DOAJ | 2020
|E03-5 TIDAL CURRENT SIMULATION USING THE FORECASTED WEATHER DATA
British Library Conference Proceedings | 2005
|Comparison of Observed and Forecasted Sea Levels Along the West Florida Coast
British Library Conference Proceedings | 1998
|Artificial Neural Network-Forecasted Compression Strength of Alkaline-Activated Slag Concretes
DOAJ | 2022
|