Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Seismic Performance Evaluation of Multi-Storey Building Having Soft Storey With Different Location of Shear Walls
Present scenario growth of Multistory building is incredibly high attributable to fast growth everywhere around the globe. Open first story is usually provided for congested parking space, reception lobbies, party areas or any purpose in multistory building. However just in case of multistory building with soft story provides reduced performance. There are numerous aspects that effects on the behavior of multistory building like irregular plan within the structure. In the present work, study of various locations of weak stories is being considered for the analysis. To study of various locations on the seismic behavior of multistory building, linear static analysis (ESA) and linear dynamic analysis (RSA) in ETABs 2016 version is applied. Some seismic constraints like time period, story shear, story displacement, story drift and base shear are tried. The seismic behaviors of multistorey building with soft stories are administered.
Seismic Performance Evaluation of Multi-Storey Building Having Soft Storey With Different Location of Shear Walls
Present scenario growth of Multistory building is incredibly high attributable to fast growth everywhere around the globe. Open first story is usually provided for congested parking space, reception lobbies, party areas or any purpose in multistory building. However just in case of multistory building with soft story provides reduced performance. There are numerous aspects that effects on the behavior of multistory building like irregular plan within the structure. In the present work, study of various locations of weak stories is being considered for the analysis. To study of various locations on the seismic behavior of multistory building, linear static analysis (ESA) and linear dynamic analysis (RSA) in ETABs 2016 version is applied. Some seismic constraints like time period, story shear, story displacement, story drift and base shear are tried. The seismic behaviors of multistorey building with soft stories are administered.
Seismic Performance Evaluation of Multi-Storey Building Having Soft Storey With Different Location of Shear Walls
Kashif Ahmer, (Autor:in) / Sharat. S. Chouka (Autor:in) / Blue Eyes Intelligence Engineering and Sciences Publication(BEIESP)
30.09.2020
oai:zenodo.org:5848485
International Journal of Innovative Technology and Exploring Engineering (IJITEE) 9(11) 50-55
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Seismic Performance of Multi-storey RC Building with Coupled Shear Walls
Springer Verlag | 2021
|Seismic Strength of Reinforced Multi-Storey Masonry Walls
Trans Tech Publications | 2014
|Seismic Analysis of Multi-storey Building on Sloping Ground with Ground, Middle and Top Soft Storey
Springer Verlag | 2021
|