Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Dynamic fail-safe behaviour of steel structures
The fundamental behaviour and the capacity of steel structures subjected to loss of interior load-bearing elements are studied. The ultimate load-bearing and deformation capacity of certain beam-to-column connections and the dynamic fail-safe behaviour of some ordinary steel structures are investigated in detail. A number of different geometrical models of steel structures in the area of primary damage are analysed. Both bending and catenary action of the models are treated and the strength properties of both members and connections are considered. Two types of connections are investigated, viz. the "bolted heel connection" and the bolted end-plate connection (with a degree of moment rigidity of 25%). No stability problems are treated. A rigid-body method of analysis is applied. Design methods for the bolted heel and bolted end-plate connections under catenary action are proposed, which safely predict the over-all behaviour and the ultimate load-bearing and deformation capacity of each connection. For structures having these two types of connections, the static damage endurance capacity under catenary action is approximately equal. The applicability and accuracy of the riqid-body method is evaluated. The accuracy is determined by comparison with an elasto-plastic vibration theory and an equivalent mass-spring method. The rigid-body model proves to be a suitable model in order to determine the failsafe behaviour of most steel structures. The ultimate dynamic load-bearing capacity under bending action regarding member characteristics and under catenary action regarding partly member characteristics and partly joint characteristics is evaluated in great detail. It is found that the dynamic capacity under bending action approximately equals the static one provided that the greater deformations obtained under dynamic conditions can be absorbed. No regard to the time of removal of the load-bearing element is thus necessary if only the deformation capacity of the structure is verified. Also, strain-hardening effects ...
Dynamic fail-safe behaviour of steel structures
The fundamental behaviour and the capacity of steel structures subjected to loss of interior load-bearing elements are studied. The ultimate load-bearing and deformation capacity of certain beam-to-column connections and the dynamic fail-safe behaviour of some ordinary steel structures are investigated in detail. A number of different geometrical models of steel structures in the area of primary damage are analysed. Both bending and catenary action of the models are treated and the strength properties of both members and connections are considered. Two types of connections are investigated, viz. the "bolted heel connection" and the bolted end-plate connection (with a degree of moment rigidity of 25%). No stability problems are treated. A rigid-body method of analysis is applied. Design methods for the bolted heel and bolted end-plate connections under catenary action are proposed, which safely predict the over-all behaviour and the ultimate load-bearing and deformation capacity of each connection. For structures having these two types of connections, the static damage endurance capacity under catenary action is approximately equal. The applicability and accuracy of the riqid-body method is evaluated. The accuracy is determined by comparison with an elasto-plastic vibration theory and an equivalent mass-spring method. The rigid-body model proves to be a suitable model in order to determine the failsafe behaviour of most steel structures. The ultimate dynamic load-bearing capacity under bending action regarding member characteristics and under catenary action regarding partly member characteristics and partly joint characteristics is evaluated in great detail. It is found that the dynamic capacity under bending action approximately equals the static one provided that the greater deformations obtained under dynamic conditions can be absorbed. No regard to the time of removal of the load-bearing element is thus necessary if only the deformation capacity of the structure is verified. Also, strain-hardening effects ...
Dynamic fail-safe behaviour of steel structures
Girhammar, Ulf Arne (Autor:in)
01.01.1980
06D
Hochschulschrift
Elektronische Ressource
Englisch
Dynamic fail-safe behaviour of steel skeleton structures having bolted connections
UB Braunschweig | 1980
|Integrating Fail-Safe and Safe-to-Fail practices in resilience planning
Springer Verlag | 2024
|