Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Pengaruh Variasi Ketebalan Selimut Beton Terhadap Lentur Balok Beton Bertulang Pasca Bakar
High temperatures at the time of the fire have a considerable influence on the residual strength of existing concrete. So that it would also result in the use of the building after the fire. The purpose of the study was to assess the extent of the percentage reduction in the compressive strength and flexural strength in the postcombustion reinforced concrete beams with concrete cover thickness and combustion with different duration. The research method by giving a different duration of combustion in 6 hours and 8 hours to beam test specimen measuring 150 mm x 200 mm x 600 mm with a thick concrete cover of 2 cm, 3 cm, 4 cm and 5 cm with the quality of concrete fc' 22,5 MPa the test beam to the age of 28 days. The result taken from the test will be displayed in a graph of the relations between the length of the combustion duration and a decrease in flexural strength that occurs in any concrete covers. The result is the percentage decrease in the flexural strength smaller as thick blankets. The test results showed that the percentage decrease in the covers 2 cm on burning six hours by 19.72 % and 30.25 % in burning 8 hours. At 3 cm thick blanket large consecutive decrease 10.72 % at 6 hours and burning of 23.58 % on burning eight hours. At 4 cm thick blanket was 6.63% on combustion 6 hours , and 22.09 % on burning eight hours. While on the covers 5 cm was 5.97% at 6 hours and burning of 21.64 % on burning 8 hours. While the compressive strength after burning 6 hours is 19.26 MPa with decreased 15.44 % , and the compressive strength in the burning of 8 hours is 17.74 MPa to 22.11 % decline from the beginning without burning compressive strength of 22.78 MPaKata kunci : flexural strength, concrete cover, after fire concrete, concrete beams
Pengaruh Variasi Ketebalan Selimut Beton Terhadap Lentur Balok Beton Bertulang Pasca Bakar
High temperatures at the time of the fire have a considerable influence on the residual strength of existing concrete. So that it would also result in the use of the building after the fire. The purpose of the study was to assess the extent of the percentage reduction in the compressive strength and flexural strength in the postcombustion reinforced concrete beams with concrete cover thickness and combustion with different duration. The research method by giving a different duration of combustion in 6 hours and 8 hours to beam test specimen measuring 150 mm x 200 mm x 600 mm with a thick concrete cover of 2 cm, 3 cm, 4 cm and 5 cm with the quality of concrete fc' 22,5 MPa the test beam to the age of 28 days. The result taken from the test will be displayed in a graph of the relations between the length of the combustion duration and a decrease in flexural strength that occurs in any concrete covers. The result is the percentage decrease in the flexural strength smaller as thick blankets. The test results showed that the percentage decrease in the covers 2 cm on burning six hours by 19.72 % and 30.25 % in burning 8 hours. At 3 cm thick blanket large consecutive decrease 10.72 % at 6 hours and burning of 23.58 % on burning eight hours. At 4 cm thick blanket was 6.63% on combustion 6 hours , and 22.09 % on burning eight hours. While on the covers 5 cm was 5.97% at 6 hours and burning of 21.64 % on burning 8 hours. While the compressive strength after burning 6 hours is 19.26 MPa with decreased 15.44 % , and the compressive strength in the burning of 8 hours is 17.74 MPa to 22.11 % decline from the beginning without burning compressive strength of 22.78 MPaKata kunci : flexural strength, concrete cover, after fire concrete, concrete beams
Pengaruh Variasi Ketebalan Selimut Beton Terhadap Lentur Balok Beton Bertulang Pasca Bakar
Fitriana, Anjany Ayu (Autor:in) / Hidayati, Ari Nur (Autor:in)
23.10.2017
doi:10.32497/wahanats.v22i1.897
Wahana Teknik Sipil: Jurnal Pengembangan Teknik Sipil; Vol 22, No 1 (2017): Wahana Teknik Sipil; 29-39 ; 2527-4333 ; 0853-8727 ; 10.32497/wahanats.v22i1
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
PENGARUH VARIASI JARAK TULANGAN SENGKANG SPIRAL TERHADAP KUAT LENTUR BALOK BETON BERTULANG
DOAJ | 2020
|PENGARUH VARIASI JARAK TULANGAN SENGKANG SPIRAL TERHADAP KUAT LENTUR BALOK BETON BERTULANG
BASE | 2020
|PENGARUH PENAMBAHAN SERAT ROVING TERHADAP KAPASITAS LENTUR BALOK BETON BERTULANG
BASE | 2012
|PENGARUH LUAS BIDANG REKATAN LAPIS GFRP TERHADAP KAPASITAS LENTUR BALOK BETON BERTULANG
BASE | 2012
|BASE | 2013
|