Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Study on crack width and crack resistance of eccentrically tensioned steel-reinforced concrete members prestressed by CFRP tendons
In recent decades, steel-reinforced concrete (SRC) members under eccentrical tension have been adopted more frequently in modern buildings due to the constraints of more complex structural design/detailing that accompanying contemporary architectural creations. Crack resistance of this type of structures has become a critical design consideration but received insufficient research attention in the past. In this context, the anti-cracking performance of prestressed SRC columns reinforced with CFRP tendons under eccentric tensile loads is investigated experimentally and analytically with the following first-hand experimental validations: 1) prestressed CFRP tendons can well strengthen SRC columns under eccentric tensile load and restrain the crack propagation; 2) an increase in the load eccentricity progressively weakened the influence of prestressing tension level on the cracking load; 3) specimens with the higher prestressed tension level, larger longitudinal reinforcement diameter, and flange thickness exhibited greater crack resistance capacity. Furthermore, the plane-section assumption was also validated in this study. A test data-enhanced analytical method was proposed for determining the cracking load of PSRC columns.
Study on crack width and crack resistance of eccentrically tensioned steel-reinforced concrete members prestressed by CFRP tendons
In recent decades, steel-reinforced concrete (SRC) members under eccentrical tension have been adopted more frequently in modern buildings due to the constraints of more complex structural design/detailing that accompanying contemporary architectural creations. Crack resistance of this type of structures has become a critical design consideration but received insufficient research attention in the past. In this context, the anti-cracking performance of prestressed SRC columns reinforced with CFRP tendons under eccentric tensile loads is investigated experimentally and analytically with the following first-hand experimental validations: 1) prestressed CFRP tendons can well strengthen SRC columns under eccentric tensile load and restrain the crack propagation; 2) an increase in the load eccentricity progressively weakened the influence of prestressing tension level on the cracking load; 3) specimens with the higher prestressed tension level, larger longitudinal reinforcement diameter, and flange thickness exhibited greater crack resistance capacity. Furthermore, the plane-section assumption was also validated in this study. A test data-enhanced analytical method was proposed for determining the cracking load of PSRC columns.
Study on crack width and crack resistance of eccentrically tensioned steel-reinforced concrete members prestressed by CFRP tendons
Deng Y. (Autor:in) / Gui J. (Autor:in) / Zhang H. (Autor:in) / Taliercio A. (Autor:in) / Zhang P. (Autor:in) / Wong S. H. F. (Autor:in) / Sukontasukkul P. (Autor:in) / Khan A. (Autor:in) / Li L. (Autor:in) / Tang Y. (Autor:in)
01.01.2022
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Time-Dependent Flexural Crack Width Prediction of Concrete Beams Prestressed with CFRP tendons
British Library Conference Proceedings | 2003
|Retrofitting of Prestressed Concrete Beams with Exterior Post-Tensioned CFRP Tendons
British Library Conference Proceedings | 1997
|Crack width evaluation in post-tensioned prestressed concrete bridge deck slabs
British Library Conference Proceedings | 2007
|Calculation of Crack Width of Steel-Concrete Composite Beam Prestressed with Internal Tendons
Trans Tech Publications | 2014
|