NDOOR AIR QUALITY IN ADMINISTRATION ROOM UNIVERSITY HASANUDDIN MAKASSAR
Indoor air quality affects the human health conditions who are in the room, such as the emergence of a complaint Sick Building Syndrome (SBS). The term is used for health problems related to indoor air quality that can be caused by various factors such as physical, including biological chemistry in this case the air microbiology. This research aims to determine the indoor air quality in the administration room of Hasanuddin University Makassar. This study was an observational study design. This study uses 15 faculties and Rectorat building consisting of 21 rooms as sample points. The result of the research shows that there are 2 rooms with total number of germs above the threshold (> 700 Colonies / m3) with total germs of 897 and 769, respectively 9 with temperatures not qualified because they have room temperature at <18 ° C,> 26 ° C and there are 8 rooms with room humidity not eligible for having> 60% or <40% moisture. There are 7 rooms identified pathogens such as Staphylococcus aureus bacteria, Pseudomonas aeruginosa, Pseudomonas aeruginosa, P.aeruginosa, and candida sp
NDOOR AIR QUALITY IN ADMINISTRATION ROOM UNIVERSITY HASANUDDIN MAKASSAR
Indoor air quality affects the human health conditions who are in the room, such as the emergence of a complaint Sick Building Syndrome (SBS). The term is used for health problems related to indoor air quality that can be caused by various factors such as physical, including biological chemistry in this case the air microbiology. This research aims to determine the indoor air quality in the administration room of Hasanuddin University Makassar. This study was an observational study design. This study uses 15 faculties and Rectorat building consisting of 21 rooms as sample points. The result of the research shows that there are 2 rooms with total number of germs above the threshold (> 700 Colonies / m3) with total germs of 897 and 769, respectively 9 with temperatures not qualified because they have room temperature at <18 ° C,> 26 ° C and there are 8 rooms with room humidity not eligible for having> 60% or <40% moisture. There are 7 rooms identified pathogens such as Staphylococcus aureus bacteria, Pseudomonas aeruginosa, Pseudomonas aeruginosa, P.aeruginosa, and candida sp
NDOOR AIR QUALITY IN ADMINISTRATION ROOM UNIVERSITY HASANUDDIN MAKASSAR
Muhammad, Arief Pawennari (Autor:in) / Daud, Anwar (Autor:in)
19.07.2018
Prosiding Fakultas Kesehatan Masyarakat Universitas Halu Oleo; Vol 1, No 1 (2018): Seminar Nasional "Kita Tingkatkan Mutu Profesi di Bidang Kesehatan Regional Timur untuk Berdaya Saing Secara Nasional"
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690