The Establishment of Performance Verification Procedures for Fourier Transform Infrared Spectrometers
An integral part of any laboratory Quality Management System (QMS) is the ability to verify an analytical instrument0s performance prior to analyzing ocial samples. Performance verification procedures provide the instrument user the means to assess whether a system is functioning properly. They are a routine predetermined set of tests and acceptance criteria that can be provided by the instrument manufacturer and/or established by the laboratory itself. Performance verification procedures that have been established for a Fourier transform infrared (FT-IR) microscope system outfitted with a macro sampling accessory allow the user to determine the daily and/or annual functionality of the instrument. Specifications were established for the IR microscope operating in transmission, reflection/absorption (R/A) and attenuated total reflection (ATR) sampling modes. The specifications for the macro sampling accessory were established for transmission and ATR sampling modes only. The acceptance criterion for each performance verification specification was calculated from a series of measurements made using each accessory and sampling mode. The performance verification procedures, as well as their associated specification and acceptance criteria described in this study, are general enough that they can be applied to FT-IR instruments from dierent manufacturers.
The Establishment of Performance Verification Procedures for Fourier Transform Infrared Spectrometers
An integral part of any laboratory Quality Management System (QMS) is the ability to verify an analytical instrument0s performance prior to analyzing ocial samples. Performance verification procedures provide the instrument user the means to assess whether a system is functioning properly. They are a routine predetermined set of tests and acceptance criteria that can be provided by the instrument manufacturer and/or established by the laboratory itself. Performance verification procedures that have been established for a Fourier transform infrared (FT-IR) microscope system outfitted with a macro sampling accessory allow the user to determine the daily and/or annual functionality of the instrument. Specifications were established for the IR microscope operating in transmission, reflection/absorption (R/A) and attenuated total reflection (ATR) sampling modes. The specifications for the macro sampling accessory were established for transmission and ATR sampling modes only. The acceptance criterion for each performance verification specification was calculated from a series of measurements made using each accessory and sampling mode. The performance verification procedures, as well as their associated specification and acceptance criteria described in this study, are general enough that they can be applied to FT-IR instruments from dierent manufacturers.
The Establishment of Performance Verification Procedures for Fourier Transform Infrared Spectrometers
Lanzarotta, Adam (Autor:in) / Witkowski, Mark (Autor:in) / Andria, Sara (Autor:in) / Crowe, John (Autor:in)
13.08.2015
Journal of Regulatory Science; Vol. 3 No. 1 (2015); 1-8 ; 2377-3537
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch