Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Lap splice in glass fiber reinforced polymer‐reinforced concrete rectangular columns subjected to cyclic‐reversed loads
This study presents the experimental results of nine full-scale lap spliced glass-fiber reinforced polymer (GFRP) reinforced concrete (RC) columns, and one additional reference steel-RC column with lap splices, under axial and cyclic-reversed loads. The test parameters included type of reinforcement, lap splice length of longitudinal reinforcement, transverse reinforcement spacing, and the effect of using steel fiber-reinforced concrete (SFRC). Test results indicated that a splice length of 60 times the diameter of the longitudinal column bar was adequate in transferring the full bond forces along the splice length and were able to maintain the lateral load carrying capacity when subjected to higher levels of axial loads and drift ratios. In addition, lap spliced GFRP-RC columns with closely spaced transverse reinforcement achieved high levels of deformability. Furthermore, the use of SFRC in columns with inadequate splice increased the peak lateral strength and the energy dissipation of the specimens. ; February 2017
Lap splice in glass fiber reinforced polymer‐reinforced concrete rectangular columns subjected to cyclic‐reversed loads
This study presents the experimental results of nine full-scale lap spliced glass-fiber reinforced polymer (GFRP) reinforced concrete (RC) columns, and one additional reference steel-RC column with lap splices, under axial and cyclic-reversed loads. The test parameters included type of reinforcement, lap splice length of longitudinal reinforcement, transverse reinforcement spacing, and the effect of using steel fiber-reinforced concrete (SFRC). Test results indicated that a splice length of 60 times the diameter of the longitudinal column bar was adequate in transferring the full bond forces along the splice length and were able to maintain the lateral load carrying capacity when subjected to higher levels of axial loads and drift ratios. In addition, lap spliced GFRP-RC columns with closely spaced transverse reinforcement achieved high levels of deformability. Furthermore, the use of SFRC in columns with inadequate splice increased the peak lateral strength and the energy dissipation of the specimens. ; February 2017
Lap splice in glass fiber reinforced polymer‐reinforced concrete rectangular columns subjected to cyclic‐reversed loads
01.01.2016
Hochschulschrift
Elektronische Ressource
Englisch
Lap Splice in GFRP-RC Rectangular Columns Subjected to Cyclic-Reversed Loads
Online Contents | 2017
|Lap Splice in GFRP-RC Rectangular Columns Subjected to Cyclic-Reversed Loads
Online Contents | 2016
|