Transient behavior of wind towers grounding systems under lightning strikes
Wind turbines, because of their height and localization, are frequently subject to direct lightning strikes. Thus, the investigation on the performance of their grounding system is of paramount interest for the prediction of the potential threats either for people working in (or animals passing through) the wind farm area and for the power and control units installed in close proximity of the turbine towers. In this paper,we perform a comprensive study of the transient behavior of the earthing systems of wind turbines. The analysis is conducted in the frequency domain and an hybrid approach, based on circuit theory and Method of Moments, is adopted to fully account for resistive, inductive and capacitive couplings between elements of the ground system. The actual transient behavior is obtained by means of an Inverse Fourier Transform. The results, computed considering a typical wind turbine grounding system configuration, provide more insight on the nature of the early-time transient response of grounding systems and allow to draw up useful design guidelines.
Transient behavior of wind towers grounding systems under lightning strikes
Wind turbines, because of their height and localization, are frequently subject to direct lightning strikes. Thus, the investigation on the performance of their grounding system is of paramount interest for the prediction of the potential threats either for people working in (or animals passing through) the wind farm area and for the power and control units installed in close proximity of the turbine towers. In this paper,we perform a comprensive study of the transient behavior of the earthing systems of wind turbines. The analysis is conducted in the frequency domain and an hybrid approach, based on circuit theory and Method of Moments, is adopted to fully account for resistive, inductive and capacitive couplings between elements of the ground system. The actual transient behavior is obtained by means of an Inverse Fourier Transform. The results, computed considering a typical wind turbine grounding system configuration, provide more insight on the nature of the early-time transient response of grounding systems and allow to draw up useful design guidelines.
Transient behavior of wind towers grounding systems under lightning strikes
ARANEO, Rodolfo (Autor:in) / CELOZZI, Salvatore (Autor:in) / Araneo, Rodolfo / Celozzi, Salvatore
01.01.2016
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
British Library Online Contents | 2000
|Engineering Index Backfile | 1945
Foil absorbs lightning strikes
British Library Online Contents | 2004
Protecting planes from lightning strikes
British Library Online Contents | 2019
|Lightning strikes concrete pavement in Georgia
Engineering Index Backfile | 1930
|