Energy efficiency for typical 2-floor buildings in Portugal
The purpose of this paper is to develop a relative evaluation, from the energetic point of view, of different building layouts. Buildings can be classified, according to their position within the lot, as perimeter yard buildings, rear yard buildings, and side yard buildings. This classification covers the layout solutions traditionally adopted by architects for 2-floor residential buildings. The thermal performance of each building layout was evaluated through the quantification of its energetic consumption (per square meter of built area), for the heating and cooling seasons, and according to the geographic orientation. The simulation tool used in this evaluation is based on the Transfer Function Method. The results obtained showed that the rear yard buildings have the better thermal performance, with an average energy consumption that is around 40% lower than in the other cases. In addition, for all building layouts studied, the North-South orientation requires the minimum energetic consumption to maintain comfortable indoor air temperature. ; Fundação para a Ciência e a Tecnologia (FCT)
Energy efficiency for typical 2-floor buildings in Portugal
The purpose of this paper is to develop a relative evaluation, from the energetic point of view, of different building layouts. Buildings can be classified, according to their position within the lot, as perimeter yard buildings, rear yard buildings, and side yard buildings. This classification covers the layout solutions traditionally adopted by architects for 2-floor residential buildings. The thermal performance of each building layout was evaluated through the quantification of its energetic consumption (per square meter of built area), for the heating and cooling seasons, and according to the geographic orientation. The simulation tool used in this evaluation is based on the Transfer Function Method. The results obtained showed that the rear yard buildings have the better thermal performance, with an average energy consumption that is around 40% lower than in the other cases. In addition, for all building layouts studied, the North-South orientation requires the minimum energetic consumption to maintain comfortable indoor air temperature. ; Fundação para a Ciência e a Tecnologia (FCT)
Energy efficiency for typical 2-floor buildings in Portugal
Bragança, L. (Autor:in) / Almeida, Manuela Guedes de (Autor:in) / Mendes, José F. G. (Autor:in)
01.12.2000
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Springer Verlag | 2018
|Energy renovation saving potentials of typical Finnish buildings
British Library Conference Proceedings | 2008
|