AbstractDistribution channels and concrete substation PT. PLN is the location Aviation Authorityoffice. Air network is not allowed in the Airport Authority, the location of the barrier andMeasuring Equipment (APP) placed near the concrete substation. The distance between thesubstation building concrete with Class II BIM Port Health Ketaping Pariaman is 700 meters.Attached power system Phasa P2/33 3 kVA and is the type of cable used NYFGbY groundcable. In the distribution network located far from the load, rating barrier for 50 Amperepower used, the size of the cable cross-section used for the 700 meter channel length is 4 x 35mm2. For the channel length of 10 meters is used a large cross-section cable NYY 4 x 6 mm2.To drop the voltage channel 700 meters long and 10 meters of copper cable core CU = 7.9Volts and 2.5 Volts. Loss and Loss for power (losses) for a distance of 700 meters of channellength with copper cable and 50 Ampere load when the load is 100% 1,890,000 Watt. Lossand Loss for power (losses) for a distance of 10 meters of channel length with copper cableand 50 Ampere load is 108,000 Watt.
ANALISIS DAMPAK PENEMPATAN ALAT PENGUKUR DAN PEMBATAS (APP) TERHADAP BEBAN (Aplikasi: Bandara Internasional Minang Kabau)
AbstractDistribution channels and concrete substation PT. PLN is the location Aviation Authorityoffice. Air network is not allowed in the Airport Authority, the location of the barrier andMeasuring Equipment (APP) placed near the concrete substation. The distance between thesubstation building concrete with Class II BIM Port Health Ketaping Pariaman is 700 meters.Attached power system Phasa P2/33 3 kVA and is the type of cable used NYFGbY groundcable. In the distribution network located far from the load, rating barrier for 50 Amperepower used, the size of the cable cross-section used for the 700 meter channel length is 4 x 35mm2. For the channel length of 10 meters is used a large cross-section cable NYY 4 x 6 mm2.To drop the voltage channel 700 meters long and 10 meters of copper cable core CU = 7.9Volts and 2.5 Volts. Loss and Loss for power (losses) for a distance of 700 meters of channellength with copper cable and 50 Ampere load when the load is 100% 1,890,000 Watt. Lossand Loss for power (losses) for a distance of 10 meters of channel length with copper cableand 50 Ampere load is 108,000 Watt.
ANALISIS DAMPAK PENEMPATAN ALAT PENGUKUR DAN PEMBATAS (APP) TERHADAP BEBAN (Aplikasi: Bandara Internasional Minang Kabau)
Syarwi, Yayan (Autor:in) / Ridal, Yani (Autor:in)
12.09.2013
ABSTRACT OF UNDERGRADUATE RESEARCH, FACULTY OF INDUSTRIAL TECHNOLOGY, BUNG HATTA UNIVERSITY; Vol. 2 No. 1 (2013): ABSTRAK DAN ARTIKEL PRODI TEKNIK ELEKTRO ; JURNAL FAKULTAS TEKNIK INDUSTRI; Vol 2 No 1 (2013): ABSTRAK DAN ARTIKEL PRODI TEKNIK ELEKTRO
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Dampak Pembangunan Bandara Internasional Yogyakarta Terhadap Perubahan Penggunaan Lahan
DOAJ | 2023
|Mitigasi dampak kebisingan bandara terhadap kehidupan pemukiman sekitar bandara SSK II Pekanbaru
BASE | 2021
|DOAJ | 2020
|