Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
On the Performance of Night Ventilation in a Historic Office Building in Nordic Climate
The effect of mechanical night ventilation on thermal comfort and electricity use for cooling of a typical historic office building in north-central Sweden was assessed. IDA-ICE simulation program was used to model the potential for improving thermal comfort and electricity savings by applying night ventilation cooling. Parametric study comprised different outdoor climates, flow rates, cooling machine’s coefficient of performance and ventilation units’ specific fan power values. Additionally, the effect of different door schemes (open or closed) on thermal comfort in offices was investigated. It was shown that night ventilation cannot meet the building’s total cooling demand and auxiliary active cooling is required, although the building is located in a cold climate. Night ventilation had the potential in decreasing the percentage of exceedance hours in offices by up to 33% and decreasing the total electricity use for cooling by up to 40%. More electricity is saved with higher night ventilation rates. There is, however, a maximum beneficial ventilation rate above which the increase in electricity use in fans outweighs the decrease in electricity use in cooling machine. It depends on thermal mass capacity of the building, cooling machine´s coefficient of performance, design ventilation rate, and available night ventilation cooling potential (ambient air temperature).
On the Performance of Night Ventilation in a Historic Office Building in Nordic Climate
The effect of mechanical night ventilation on thermal comfort and electricity use for cooling of a typical historic office building in north-central Sweden was assessed. IDA-ICE simulation program was used to model the potential for improving thermal comfort and electricity savings by applying night ventilation cooling. Parametric study comprised different outdoor climates, flow rates, cooling machine’s coefficient of performance and ventilation units’ specific fan power values. Additionally, the effect of different door schemes (open or closed) on thermal comfort in offices was investigated. It was shown that night ventilation cannot meet the building’s total cooling demand and auxiliary active cooling is required, although the building is located in a cold climate. Night ventilation had the potential in decreasing the percentage of exceedance hours in offices by up to 33% and decreasing the total electricity use for cooling by up to 40%. More electricity is saved with higher night ventilation rates. There is, however, a maximum beneficial ventilation rate above which the increase in electricity use in fans outweighs the decrease in electricity use in cooling machine. It depends on thermal mass capacity of the building, cooling machine´s coefficient of performance, design ventilation rate, and available night ventilation cooling potential (ambient air temperature).
On the Performance of Night Ventilation in a Historic Office Building in Nordic Climate
Khosravi Bakhtiari, Hossein (Autor:in) / Akander, Jan (Autor:in) / Cehlin, Mathias (Autor:in) / Hayati, Abolfazl (Autor:in)
01.01.2020
Scopus 2-s2.0-85090578033
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Evaluation of Thermal Comfort and Night Ventilation in a Historic Office Building in Nordic Climate
BASE | 2020
|Feasibility of mechanically driven night ventilation in a high profile office building
British Library Conference Proceedings | 2008
|Night ventilation effectiveness in various types of office buildings
British Library Conference Proceedings | 1998
|