Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Performance evaluation of non-conventional constructions: case study in a temperate climate
The development of new construction solutions is fundamental to enhance the building stock energy performance, and thus promote sustainable development in the building sector. These solutions must be sensitive to both the energy performance and the environmental performance. The aim of the work presented in this paper is the comparison, in terms of energy performance, between heavyweight conventional solutions and mixed-weight non-conventional envelope solutions. These solutions were applied in a test building built at the University of Minho’s Azurém campus. The evaluation was carried out by means of data analysis of in situ measurements, and also the use of energy and daylighting simulation tools. Prior to the simulations, it was necessary to calibrate the model and create a weather file representative of the real weather conditions. From this evaluation, it was possible to assess the potentialities of different construction solutions. The non-conventional solution presented a similar energy performance but a better environmental performance than the conventional solution, due to the use of low embodied energy materials. It was also proved that, with minor modifications, the non-conventional solution can produce a better energy performance than the conventional one, evidencing the potential of application of these solutions.
Performance evaluation of non-conventional constructions: case study in a temperate climate
The development of new construction solutions is fundamental to enhance the building stock energy performance, and thus promote sustainable development in the building sector. These solutions must be sensitive to both the energy performance and the environmental performance. The aim of the work presented in this paper is the comparison, in terms of energy performance, between heavyweight conventional solutions and mixed-weight non-conventional envelope solutions. These solutions were applied in a test building built at the University of Minho’s Azurém campus. The evaluation was carried out by means of data analysis of in situ measurements, and also the use of energy and daylighting simulation tools. Prior to the simulations, it was necessary to calibrate the model and create a weather file representative of the real weather conditions. From this evaluation, it was possible to assess the potentialities of different construction solutions. The non-conventional solution presented a similar energy performance but a better environmental performance than the conventional solution, due to the use of low embodied energy materials. It was also proved that, with minor modifications, the non-conventional solution can produce a better energy performance than the conventional one, evidencing the potential of application of these solutions.
Performance evaluation of non-conventional constructions: case study in a temperate climate
Silva, Pedro C. P. (Autor:in) / Almeida, Manuela Guedes de (Autor:in) / Bragança, L. (Autor:in) / Mesquita, Vasco (Autor:in)
01.09.2012
doi:10.1016/j.applthermaleng.2012.03.016
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
THE THERMAL PERFORMANCE OF STANDARD AUSTRALIAN DOMESTIC CONSTRUCTIONS IN A TEMPERATE CLIMATE
Taylor & Francis Verlag | 1983
|DataCite | 2021
|Green roof yearly performance: A case study in a highly insulated building under temperate climate
Online Contents | 2012
|