Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Punching of reinforced concrete flat slabs – Rational use of high strength concrete
PTDC/ECI-EST/30511/2017; SFRH/BD/76242/2011; The authors are grateful to CIMPOR for providing the cement and Sika for providing VISCOCRETE 20HE and SIKACRETE HD. ; This paper deals with punching of reinforced high strength concrete (HSC) flat slabs. Despite the use of HSC increased significantly in the last years, the experimental research on punching behavior of HSC slabs is still limited. Furthermore, most of this past research adopted concrete compressive strength lower than 90 MPa. In a previous work by this research group three specimens with concrete compressive strength around 120 MPa and one with normal strength concrete (NSC) were tested. The present work represents the continuation of the previous activity and it is focused on the rational use of HSC. Four specimens with HSC and one of NSC were tested under monotonic vertical loading. The HSC was placed only in the slab-column connection region and it was limited to a thin layer in the compressive zone, in order to have a more economical and sustainable solution. This rational use of the HSC showed excellent results in terms of punching strength. Limiting the HSC to a thin layer in the compressive zone resulted in an almost equal punching strength to that obtained with the slab entirely casted in HSC. ; authorsversion ; published
Punching of reinforced concrete flat slabs – Rational use of high strength concrete
PTDC/ECI-EST/30511/2017; SFRH/BD/76242/2011; The authors are grateful to CIMPOR for providing the cement and Sika for providing VISCOCRETE 20HE and SIKACRETE HD. ; This paper deals with punching of reinforced high strength concrete (HSC) flat slabs. Despite the use of HSC increased significantly in the last years, the experimental research on punching behavior of HSC slabs is still limited. Furthermore, most of this past research adopted concrete compressive strength lower than 90 MPa. In a previous work by this research group three specimens with concrete compressive strength around 120 MPa and one with normal strength concrete (NSC) were tested. The present work represents the continuation of the previous activity and it is focused on the rational use of HSC. Four specimens with HSC and one of NSC were tested under monotonic vertical loading. The HSC was placed only in the slab-column connection region and it was limited to a thin layer in the compressive zone, in order to have a more economical and sustainable solution. This rational use of the HSC showed excellent results in terms of punching strength. Limiting the HSC to a thin layer in the compressive zone resulted in an almost equal punching strength to that obtained with the slab entirely casted in HSC. ; authorsversion ; published
Punching of reinforced concrete flat slabs – Rational use of high strength concrete
Inácio, Micael M. G. (Autor:in) / Lapi, Massimo (Autor:in) / Pinho Ramos, António (Autor:in) / DEC - Departamento de Engenharia Civil / CERIS - Polo NOVA
01.03.2020
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Reinforced High Strength Concrete in Punching Failure of Flat Slabs
British Library Conference Proceedings | 1995
|Punching strength of reinforced concrete slabs
Engineering Index Backfile | 1966
|Punching strength of reinforced concrete flat slabs without shear reinforcement
DOAJ
|A study of the punching strength of reinforced concrete flat slabs
UB Braunschweig | 1971
|