Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
High resolution measuring system for domestic hot water consumption. Development and field test
Much effort has been put in tightening the building regulations. Though, the energy usage for domestic hot water stayed unchanged constituting a bigger share of the energy pie over the years. Due to the cost, timeframe, and workload associated with instrumentation and installation, the vast majority of the DHW measurements are limited to the household level. This paper introduces a high resolution measuring technique for DHW consumption and its application in a single family house. By applying this technique, we are able to measure the duration, flow and temperature of each water draw event in the house and thus create both the temporal and spatial DHW consumption profiles. The results indicated that the duration of draws varies significantly between tapping places, i.e. the draws in the shower and in the kitchen have an average duration of 300 sec. and 20 sec., respectively. The high resolution metering system was able to record the inefficient use of DHW, at periods when the water temperature was not meeting the users’ requirements, e.g. the wasted energy at the shower depending on the usage patter varies between 25% and 42%. The measured temperature range of DHW in the household is between 52°C (kitchen) and 21°C (sink in utility room).
High resolution measuring system for domestic hot water consumption. Development and field test
Much effort has been put in tightening the building regulations. Though, the energy usage for domestic hot water stayed unchanged constituting a bigger share of the energy pie over the years. Due to the cost, timeframe, and workload associated with instrumentation and installation, the vast majority of the DHW measurements are limited to the household level. This paper introduces a high resolution measuring technique for DHW consumption and its application in a single family house. By applying this technique, we are able to measure the duration, flow and temperature of each water draw event in the house and thus create both the temporal and spatial DHW consumption profiles. The results indicated that the duration of draws varies significantly between tapping places, i.e. the draws in the shower and in the kitchen have an average duration of 300 sec. and 20 sec., respectively. The high resolution metering system was able to record the inefficient use of DHW, at periods when the water temperature was not meeting the users’ requirements, e.g. the wasted energy at the shower depending on the usage patter varies between 25% and 42%. The measured temperature range of DHW in the household is between 52°C (kitchen) and 21°C (sink in utility room).
High resolution measuring system for domestic hot water consumption. Development and field test
Marszal, Anna Joanna (Autor:in) / Valeva, Bozhana Todorova (Autor:in) / Georgieva, Viktoriya Vasileva (Autor:in) / Larsen, Olena Kalyanova (Autor:in) / Jensen, Rasmus Lund (Autor:in) / Zhang, Chen (Autor:in)
01.01.2019
Marszal , A J , Valeva , B T , Georgieva , V V , Larsen , O K , Jensen , R L & Zhang , C 2019 , ' High resolution measuring system for domestic hot water consumption. Development and field test ' , Energy Procedia , vol. 158 , no. February 2019 , pp. 2859-2864 . https://doi.org/10.1016/j.egypro.2019.01.1022
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Urban domestic water consumption
Engineering Index Backfile | 1939
|Development of a decentralized monitoring system of domestic water consumption
BASE | 2019
|Domestic water consumption benchmark development for Hong Kong
British Library Online Contents | 2007
|Domestic water consumption in large construction camp
Engineering Index Backfile | 1936