Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental and Analytical Study on Local Buckling Behavior of the Concrete-filled Thin-walled Welded Steel Columns
This paper presents an experimental investigation of the concrete filled thin-walled welded steel tubes. Square and rectangular columns are tested with and without the bond between the steel profile and concrete. In order to remove the bond in the latter columns a polyethylene (PE) film is placed inside of the steel profiles. Experimental results are verified via the finite element analysis and compared to the results obtained using the analytical calculation methods. The significance of the steel–concrete bond is evaluated, referring to the differences of the critical loads, ultimate loads and effective cross-sectional areas of the columns with and without the PE film inside and the differences are found to be considerable. It is found that the columns without the film had an up to 47% higher effective cross-sectional area to full cross-sectional area ratio. The average reduction of the effective cross-sectional area of the column having a poor bond is found to be 12%. It is also found that the resistance is often overestimated when using the analytical formulas, especially for the columns with the PE film inside.
Experimental and Analytical Study on Local Buckling Behavior of the Concrete-filled Thin-walled Welded Steel Columns
This paper presents an experimental investigation of the concrete filled thin-walled welded steel tubes. Square and rectangular columns are tested with and without the bond between the steel profile and concrete. In order to remove the bond in the latter columns a polyethylene (PE) film is placed inside of the steel profiles. Experimental results are verified via the finite element analysis and compared to the results obtained using the analytical calculation methods. The significance of the steel–concrete bond is evaluated, referring to the differences of the critical loads, ultimate loads and effective cross-sectional areas of the columns with and without the PE film inside and the differences are found to be considerable. It is found that the columns without the film had an up to 47% higher effective cross-sectional area to full cross-sectional area ratio. The average reduction of the effective cross-sectional area of the column having a poor bond is found to be 12%. It is also found that the resistance is often overestimated when using the analytical formulas, especially for the columns with the PE film inside.
Experimental and Analytical Study on Local Buckling Behavior of the Concrete-filled Thin-walled Welded Steel Columns
Martinavičius, Deividas (Autor:in) / Augonis, Mindaugas (Autor:in) / Rui Tiago Arruda, Mário (Autor:in)
13.07.2020
doi:10.3311/PPci.15705
Periodica Polytechnica Civil Engineering; Vol. 64 No. 3 (2020); 917-927 ; 1587-3773 ; 0553-6626
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
BASE | 2020
|BASE | 2020
|Local buckling of steel plates in concrete-filled thin-walled steel tubular beam–columns
Online Contents | 2007
|Nonlinear analysis of concrete-filled thin-walled steel box columns with local buckling effects
Online Contents | 2006
|Analytical Study on Local Buckling Strength of Polygonal Thin-Walled Steel Columns
British Library Conference Proceedings | 1995
|