Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Graphite-polydimethylsiloxane composite strain sensors for in-situ structural health monitoring
Here we describe the synthesis and testing of miniature sensors for structural health monitoring. The sensors were incorporated into building materials to detect strain relaxation events within the region of elastic deformation prior to the onset of plastic deformation. Our sensors consisted of thin composite films of polydimethylsiloxane and graphite nanoparticles that conduct via tunnelling percolation. Tunnelling-percolation through elastomers with low Young's modulus is highly sensitive to deformation and gives a large piezoresistance which we use to infer the local strain. The response of sensors embedded in calcium aluminate mortar, Portland cement mortar, and very fine sand columns was compared under stress. We show that the sensors can detect micro-events where strain is redistributed locally from one direction to another and may thus be used to monitor structural integrity and provide early warning of material disaggregation.
Graphite-polydimethylsiloxane composite strain sensors for in-situ structural health monitoring
Here we describe the synthesis and testing of miniature sensors for structural health monitoring. The sensors were incorporated into building materials to detect strain relaxation events within the region of elastic deformation prior to the onset of plastic deformation. Our sensors consisted of thin composite films of polydimethylsiloxane and graphite nanoparticles that conduct via tunnelling percolation. Tunnelling-percolation through elastomers with low Young's modulus is highly sensitive to deformation and gives a large piezoresistance which we use to infer the local strain. The response of sensors embedded in calcium aluminate mortar, Portland cement mortar, and very fine sand columns was compared under stress. We show that the sensors can detect micro-events where strain is redistributed locally from one direction to another and may thus be used to monitor structural integrity and provide early warning of material disaggregation.
Graphite-polydimethylsiloxane composite strain sensors for in-situ structural health monitoring
Gaumet, Alize (Autor:in) / Ball, Richard (Autor:in) / Nogaret, Alain (Autor:in)
01.12.2021
Gaumet , A , Ball , R & Nogaret , A 2021 , ' Graphite-polydimethylsiloxane composite strain sensors for in-situ structural health monitoring ' , Sensors and Actuators A-Physical , vol. 332 , no. 113139 , 113139 . https://doi.org/10.1016/j.sna.2021.113139
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
MEMS Based Strain and Corrosion Sensors for Structural Health Monitoring
British Library Conference Proceedings | 2007
|In-situ Fatigue Sensors for Structural Health Monitoring of Highway Bridges
British Library Conference Proceedings | 2010
|Composite Structural Health Monitoring Through Use of Embedded PZT Sensors
British Library Online Contents | 2011
|Structural health monitoring in composite structures by fiber-optic sensors
BASE | 2018
|Structural health monitoring of wind towers: remote damage detection using strain sensors
British Library Online Contents | 2011
|