Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Evaluasi Desain Pencahayaan Interior Pada Ruang Pertemuan Publik Berdasarkan Nilai Intensitas Pencahayaan
The emphasis of green building design is not only based on the use of energy consumption as efficiently as possible purpose, but another important aspect that it is also the comfort factor should be considered for the occupants in the building space itself. In this paper, we evaluate the comfort factor of public meeting room at New Media Tower Building, Universitas Multimedia Nusantara (C-UMN Building). The comfort factor to be evaluated is the artificial lighting inside the room (interior) according to standards that have been standardized locally and internationally. The evaluation process includes a quantitative approach through measuring the existing conditions by utilizing photometric elements such as illuminance and uniformity. The results of this measurement can practically provide information on whether the C-UMN Building space that has been meets the criteria of the ideal standard or not. Index Terms—DIALux, Green Building, Iluminance, Uniformity
Evaluasi Desain Pencahayaan Interior Pada Ruang Pertemuan Publik Berdasarkan Nilai Intensitas Pencahayaan
The emphasis of green building design is not only based on the use of energy consumption as efficiently as possible purpose, but another important aspect that it is also the comfort factor should be considered for the occupants in the building space itself. In this paper, we evaluate the comfort factor of public meeting room at New Media Tower Building, Universitas Multimedia Nusantara (C-UMN Building). The comfort factor to be evaluated is the artificial lighting inside the room (interior) according to standards that have been standardized locally and internationally. The evaluation process includes a quantitative approach through measuring the existing conditions by utilizing photometric elements such as illuminance and uniformity. The results of this measurement can practically provide information on whether the C-UMN Building space that has been meets the criteria of the ideal standard or not. Index Terms—DIALux, Green Building, Iluminance, Uniformity
Evaluasi Desain Pencahayaan Interior Pada Ruang Pertemuan Publik Berdasarkan Nilai Intensitas Pencahayaan
Salehuddin, Muhammad (Autor:in) / Latupeirissa, Hednrico Firzandy (Autor:in)
02.04.2018
doi:10.31937/sk.v9i2.672
ULTIMA Computing; Vol 9 No 2 (2017): Ultima Computing : Jurnal Sistem Komputer; 73-77 ; Ultima Computing : Jurnal Sistem Komputer; Vol 9 No 2 (2017): Ultima Computing : Jurnal Sistem Komputer; 73-77 ; 2549-4007 ; 2355-3286
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Evaluasi Sistem Pencahayaan Ruang Belanja 212mart Yos Sudarso Rumbai Pesisir
DOAJ | 2019
|BASE | 2022
|Optimalisasi Desain Pencahayaan Alami Tipologi Ruang Kelas Gedung GKB UM dengan Analisis DIALUX EVO
DOAJ | 2024
|EVALUASI PENCAHAYAAN PADA BANGUNAN PASAR BERINGHARJO MENUJU DISAIN SARANA KOTA BERKELANJUTAN
DOAJ | 2018
|