Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
MODIFIKASI KOEFISIEN DAYA DUKUNG AKSIAL PONDASI TIANG BERDASARKAN BACK ANALYSIS PADA DATA LOADING TEST
The axial bearing capacity of the pile foundation is needed to determine the number of foundations required to carry the structural load. Calculation of the axial bearing capacity pile foundation produces a carrying capacity different from the results of loading tests in the field. The difference between the bearing capacity design with loading test result can make a waste of the number of poles used. To make effective use of the number of piles, the bearing capacity design is necessary to modify the coefficient so that bearing capacity design is closer to the results of the loading test. The result of the modification the bearing capacity of the clay soil in an increase that is not much different from the initial coefficient but is strongly influenced by the value of the internal friction angle which can make the coefficient increase twice. For cohesionless soil, ultimate base resistance there is an average value of 56.75 tsf for N-SPT 50.Keywords: Bearing capacity, Coefficient, modification, Loading test, Pile foundation
MODIFIKASI KOEFISIEN DAYA DUKUNG AKSIAL PONDASI TIANG BERDASARKAN BACK ANALYSIS PADA DATA LOADING TEST
The axial bearing capacity of the pile foundation is needed to determine the number of foundations required to carry the structural load. Calculation of the axial bearing capacity pile foundation produces a carrying capacity different from the results of loading tests in the field. The difference between the bearing capacity design with loading test result can make a waste of the number of poles used. To make effective use of the number of piles, the bearing capacity design is necessary to modify the coefficient so that bearing capacity design is closer to the results of the loading test. The result of the modification the bearing capacity of the clay soil in an increase that is not much different from the initial coefficient but is strongly influenced by the value of the internal friction angle which can make the coefficient increase twice. For cohesionless soil, ultimate base resistance there is an average value of 56.75 tsf for N-SPT 50.Keywords: Bearing capacity, Coefficient, modification, Loading test, Pile foundation
MODIFIKASI KOEFISIEN DAYA DUKUNG AKSIAL PONDASI TIANG BERDASARKAN BACK ANALYSIS PADA DATA LOADING TEST
Najib, Fauzi Lukman (Autor:in) / Dermawan, Herwan (Autor:in) / Yusuf, Rakhmat (Autor:in)
01.01.2022
doi:10.17509/k.v20i1.52339
Kokoh; Vol 20, No 1 (2022): Januari 2022; 43-56 ; 2828-5778 ; 1412-050X ; 10.17509/k.v20i1
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
BASE | 2018
|PENGARUH ELEKTROKINETIK TERHADAP DAYA DUKUNG PONDASI TIANG DI LEMPUNG MARINA
DOAJ | 2006
|PENGARUH DAYA DUKUNG PONDASI TIANG BETON BERTULANG BAMBU TERHADAP TANAH GAMBUT
DOAJ | 2019
|ANALISIS KAPASITAS DAYA DUKUNG PONDASI TIANG PANCANG DENGAN METODE US.ARMY CORPS
BASE | 2024
|