Energy performance analysis of an office building in three climate zones
Most of the studies encompassing dynamic simulations of multi-storey buildings account only for a few selected zones, to simplify, decrease simulation run-time and to reduce the complexity of the ‘to be simulated’ model. This conventional method neglects the opportunity to see the interaction between different zones as it relates to whole building performance. This paper presents fifteen individual cases of dynamic simulations of a six-storey office building with 160 zones. The energy performance analysis was conducted for three climate zones including Helsinki in Finland, London in the United Kingdom and Bucharest in Romania. For each location, the following three cases were simulated: (i) building as usual simulated according to valid national building codes; (ii) Energy-efficient (EE) case with selected necessary parameters enhanced to reduce total delivered energy demand; and (iii) nZEB case representing partial enhancement of the EE case based on the parametric analysis. The results of nZEB indicate that for Helsinki, it is possible to reduce the space-heating load by 86%, electricity consumed by lighting, appliance, and HVAC by 32%. For London, the heating load is reduced by 95%, cooling load is slightly increased, and electricity demand is decreased by 33%. For Bucharest, 92% of energy in heating can be saved, cooling energy demand was reduced by 60% and electricity consumption by 34%. Based on the nZEB cases for each location, alternative heating and cooling choices of a radiant floor panel system and radiant ceiling panel system were explored. There are small differences in absolute consumption demand for heating, cooling, and electricity for three cases in each location. The specific energy/m 2 for heating remained nearly the same in all systems for all three cases in each location. Alternative choices for heating and cooling by using Radiant Ceiling Panel (RCP) and Radiant Floor Panel (RFP) were investigated for all final nZEB cases. Marginal difference in heating energy required for space heating can ...
Energy performance analysis of an office building in three climate zones
Most of the studies encompassing dynamic simulations of multi-storey buildings account only for a few selected zones, to simplify, decrease simulation run-time and to reduce the complexity of the ‘to be simulated’ model. This conventional method neglects the opportunity to see the interaction between different zones as it relates to whole building performance. This paper presents fifteen individual cases of dynamic simulations of a six-storey office building with 160 zones. The energy performance analysis was conducted for three climate zones including Helsinki in Finland, London in the United Kingdom and Bucharest in Romania. For each location, the following three cases were simulated: (i) building as usual simulated according to valid national building codes; (ii) Energy-efficient (EE) case with selected necessary parameters enhanced to reduce total delivered energy demand; and (iii) nZEB case representing partial enhancement of the EE case based on the parametric analysis. The results of nZEB indicate that for Helsinki, it is possible to reduce the space-heating load by 86%, electricity consumed by lighting, appliance, and HVAC by 32%. For London, the heating load is reduced by 95%, cooling load is slightly increased, and electricity demand is decreased by 33%. For Bucharest, 92% of energy in heating can be saved, cooling energy demand was reduced by 60% and electricity consumption by 34%. Based on the nZEB cases for each location, alternative heating and cooling choices of a radiant floor panel system and radiant ceiling panel system were explored. There are small differences in absolute consumption demand for heating, cooling, and electricity for three cases in each location. The specific energy/m 2 for heating remained nearly the same in all systems for all three cases in each location. Alternative choices for heating and cooling by using Radiant Ceiling Panel (RCP) and Radiant Floor Panel (RFP) were investigated for all final nZEB cases. Marginal difference in heating energy required for space heating can ...
Energy performance analysis of an office building in three climate zones
Jung, Nusrat (Autor:in) / Paiho, Satu (Autor:in) / Shemeikka, Jari (Autor:in) / Lahdelma, Risto (Autor:in) / Airaksinen, Miimu (Autor:in)
01.01.2018
Jung , N , Paiho , S , Shemeikka , J , Lahdelma , R & Airaksinen , M 2018 , ' Energy performance analysis of an office building in three climate zones ' , Energy and Buildings , vol. 158 , pp. 1023-1035 . https://doi.org/10.1016/j.enbuild.2017.10.030
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Bucharest , Dynamic simulations , Energy efficiency , Energy performance , Helsinki , IDA ICE , London , Multi zone , nZEB , Office buildings , Radiant ceiling panels , Radiant floor panels , /dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energy , name=SDG 7 - Affordable and Clean Energy , /dk/atira/pure/sustainabledevelopmentgoals/responsible_consumption_and_production , name=SDG 12 - Responsible Consumption and Production , /dk/atira/pure/sustainabledevelopmentgoals/partnerships , name=SDG 17 - Partnerships for the Goals
DDC:
720
Analysis of the Thermal and Cooling Energy Performance of the Perimeter Zones in an Office Building
DOAJ | 2022
|Integrated analysis of bioclimatic building design in three climate zones in France
BASE | 2012
|Energy Performance Analysis of Kinetic Façades by Climate Zones
Springer Verlag | 2022
|