Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Behaviour of jacked and driven piles in sandy soil
As an alternative to conventional dynamic pile installation methods, pile jacking is an environmentally friendly technique that could become more widely accepted. Great concern has arisen over the performance of jacked piles as compared with that of driven piles. This paper describes a comprehensive field study that was aimed at investigating the differences and similarities between the behaviour of jacked H-piles and that of driven H-piles. The instrumented piles, varying in length from 32 to 55 m and having a design capacity of up to 3540 kN, were installed in residual soils whose properties are close to silty sands. The load test results indicate that the shaft resistance of jacked piles is generally suffer and stronger than that of driven piles, but the base resistance of jacked piles is weaker than that of driven piles. At a load level of twice the design capacity, the percentage of pile head load carried by base varies from 2% to 10% for jacked piles, with a mean value of 6%; for driven piles the percentage varies from 6% to 61% with a mean value of 38%. The back-calculated values of the shaft friction coefficient, β, were found to be in a range of 0.25-0.6 for both jacked and driven piles. A correlation was also observed between the ultimate shaft friction and the mean standard penetration test N value (N̄), which suggests that the shaft friction can be taken as 1.5N̄ to 2N̄ (kPa) for both jacked and driven H-piles. ; published_or_final_version
Behaviour of jacked and driven piles in sandy soil
As an alternative to conventional dynamic pile installation methods, pile jacking is an environmentally friendly technique that could become more widely accepted. Great concern has arisen over the performance of jacked piles as compared with that of driven piles. This paper describes a comprehensive field study that was aimed at investigating the differences and similarities between the behaviour of jacked H-piles and that of driven H-piles. The instrumented piles, varying in length from 32 to 55 m and having a design capacity of up to 3540 kN, were installed in residual soils whose properties are close to silty sands. The load test results indicate that the shaft resistance of jacked piles is generally suffer and stronger than that of driven piles, but the base resistance of jacked piles is weaker than that of driven piles. At a load level of twice the design capacity, the percentage of pile head load carried by base varies from 2% to 10% for jacked piles, with a mean value of 6%; for driven piles the percentage varies from 6% to 61% with a mean value of 38%. The back-calculated values of the shaft friction coefficient, β, were found to be in a range of 0.25-0.6 for both jacked and driven piles. A correlation was also observed between the ultimate shaft friction and the mean standard penetration test N value (N̄), which suggests that the shaft friction can be taken as 1.5N̄ to 2N̄ (kPa) for both jacked and driven H-piles. ; published_or_final_version
Behaviour of jacked and driven piles in sandy soil
01.01.2006
56
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Behaviour of jacked and driven piles in sandy soil
Online Contents | 2007
|Behaviour of jacked and driven piles in sandy soil
British Library Online Contents | 2007
|Behaviour of jacked and driven piles in sandy soil
British Library Online Contents | 2006
|Behaviour of jacked and driven piles in sandy soil
Online Contents | 2006
|