Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Post occupancy evaluation of thermal comfort and indoor air quality of office spaces in a tropical green campus building
Purpose: As suggested in many previous studies, good thermal comfort and indoor air quality (IAQ) played a significant role in ensuring human comfort, health and productivity in buildings. Hence, this study aims to evaluate the thermal comfort and IAQ conditions of open-plan office areas within a green-certified campus building through a post occupancy evaluation. Design/methodology/approach: Using the field measurement method, environmental dataloggers were positioned at three office areas during office hours to measure the levels of thermal comfort parameters, CO2 concentrations and the supply air rates. At the same time, questionnaires were distributed to the available office staff to obtain their perception of the indoor environment. The findings were then compared with the recommended environmental comfort ranges and used to calculate the thermal comfort indices. Findings: Results show that the physical parameters were generally within acceptable ranges of a local guideline. The neutral temperature based on the actual mean vote at these areas was 23.9°C, which is slightly lower than the predicted thermal neutrality of 25.2°C. From the surveyed findings, about 81% of the occupants found their thermal environment comfortable with high adaptation rates. A preference for cooler environments was found among the workers. Meanwhile, the air quality was perceived to be clean by a majority of the respondents, and the mean ventilation rate per person was identified to be sufficient. Research limitations/implications: This study focussed on the thermal environment and air quality at selected office spaces only. More work should be carried out in other regularly occupied workplaces and study areas of the green educational building to allow a more thorough analysis of the indoor air conditions. Practical implications: This paper highlights on the thermal comfort and air quality conditions of the air-conditioned office spaces in a green-certified campus building and is intended to assist the building services engineers ...
Post occupancy evaluation of thermal comfort and indoor air quality of office spaces in a tropical green campus building
Purpose: As suggested in many previous studies, good thermal comfort and indoor air quality (IAQ) played a significant role in ensuring human comfort, health and productivity in buildings. Hence, this study aims to evaluate the thermal comfort and IAQ conditions of open-plan office areas within a green-certified campus building through a post occupancy evaluation. Design/methodology/approach: Using the field measurement method, environmental dataloggers were positioned at three office areas during office hours to measure the levels of thermal comfort parameters, CO2 concentrations and the supply air rates. At the same time, questionnaires were distributed to the available office staff to obtain their perception of the indoor environment. The findings were then compared with the recommended environmental comfort ranges and used to calculate the thermal comfort indices. Findings: Results show that the physical parameters were generally within acceptable ranges of a local guideline. The neutral temperature based on the actual mean vote at these areas was 23.9°C, which is slightly lower than the predicted thermal neutrality of 25.2°C. From the surveyed findings, about 81% of the occupants found their thermal environment comfortable with high adaptation rates. A preference for cooler environments was found among the workers. Meanwhile, the air quality was perceived to be clean by a majority of the respondents, and the mean ventilation rate per person was identified to be sufficient. Research limitations/implications: This study focussed on the thermal environment and air quality at selected office spaces only. More work should be carried out in other regularly occupied workplaces and study areas of the green educational building to allow a more thorough analysis of the indoor air conditions. Practical implications: This paper highlights on the thermal comfort and air quality conditions of the air-conditioned office spaces in a green-certified campus building and is intended to assist the building services engineers ...
Post occupancy evaluation of thermal comfort and indoor air quality of office spaces in a tropical green campus building
Yong, NH (Autor:in) / Kwong, QJ (Autor:in) / Ong, KS (Autor:in) / Mumovic, D (Autor:in)
16.08.2021
Journal of Facilities Management (2021) (In press).
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Emerald Group Publishing | 2021
|Post-occupancy evaluation in indoor comfort conditions for green office buildings
DOAJ | 2022
|Green Building 2006 - Post-Occupancy Evaluation
Online Contents | 2006
Office spaces in São Paulo: post-occupancy evaluation of a high technology building
Emerald Group Publishing | 1999
|