Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Example of acrylonitrile production wastewater treatment project
Aiming at the characteristics of acrylonitrile production wastewater with high concentration of refractory organic matter, high total nitrogen concentration,high toxicity and complex composition, the combined process of “ozone catalytic oxidation+coagulation precipitation+improved A/O” was used to treat the wastewater. The process, main structure and equipment design parameters, debugging difficulties and methods were introduced, and the operation effect and cost were analyzed. The operation results showed that the process has the characteristics of shock load resistance, stable operation and convenient management. After the acrylonitrile production wastewater was treated by this combination process, the mass concentrations of COD, NH3-N, TN, SS, TN and TCN were stable at 34-97, 0.3-2.7, 9-26, 8-23, 0-0.1 mg/L, which could fully meets the indirect emission standard in Table 2 of the Petrochemical Industry Pollutant Emission Standard (GB 31571-2015), while the organic characteristic pollutant acrylonitrile in the effluent was detected to meet the emission limits in Table 3 of the Petrochemical Industry Pollutant Emission Standard(GB 31571-2015), and satisfied takeover standards in the regional centralized sewage treatment plant.
Example of acrylonitrile production wastewater treatment project
Aiming at the characteristics of acrylonitrile production wastewater with high concentration of refractory organic matter, high total nitrogen concentration,high toxicity and complex composition, the combined process of “ozone catalytic oxidation+coagulation precipitation+improved A/O” was used to treat the wastewater. The process, main structure and equipment design parameters, debugging difficulties and methods were introduced, and the operation effect and cost were analyzed. The operation results showed that the process has the characteristics of shock load resistance, stable operation and convenient management. After the acrylonitrile production wastewater was treated by this combination process, the mass concentrations of COD, NH3-N, TN, SS, TN and TCN were stable at 34-97, 0.3-2.7, 9-26, 8-23, 0-0.1 mg/L, which could fully meets the indirect emission standard in Table 2 of the Petrochemical Industry Pollutant Emission Standard (GB 31571-2015), while the organic characteristic pollutant acrylonitrile in the effluent was detected to meet the emission limits in Table 3 of the Petrochemical Industry Pollutant Emission Standard(GB 31571-2015), and satisfied takeover standards in the regional centralized sewage treatment plant.
Example of acrylonitrile production wastewater treatment project
XU Qiang (Autor:in) / QIU Xinyao (Autor:in) / LI Chunfeng (Autor:in)
2024
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
An Example for the Project Design of Electroplating Wastewater Treatment
British Library Online Contents | 2005
|Wastewater Treatment Facility Aeration Project
British Library Conference Proceedings | 1996
|A project case on treatment of photovoltaic enterprise production wastewater
DOAJ | 2024
|